EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Feasibility of Long-Term Physical Activity Measurement With a Wearable Activity Tracker in Patients With Axial Spondyloarthritis: 1-Year Longitudinal Observational Study

Emil Eirik Kvernberg Thomassen iD, Anne Therese Tveter iD, Inger Jorid Berg iD, Eirik Klami Kristianslund iD, Andrew Reiner iD, Sarah Hakim iD, Laure Gossec iD, Gary J Macfarlane iD, Annette de Thurah iD, Nina Østerås iD

JMIR Human Factors · 2025

DOI: 10.2196/68645 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift JMIR Human Factors, 2025. Verfasst von Emil Eirik Kvernberg Thomassen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Treatment of Rheumatic and Musculoskeletal Diseases, Diakonhjemmet Hospital, Diakonveien 12, Oslo, 0370, Norway, 47 95252216. Hauptthemen laut MEDLINE: Axial Spondyloarthritis, Exercise, Fitness Trackers, Spondylarthritis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Using wearable activity trackers shows promise in measuring physical activity in patients with axial spondyloarthritis (axSpA). However, little is known regarding the feasibility of long-term use.

Objectives

This study aimed to explore the feasibility of recording physical activity using a wearable activity tracker and describe wear-time patterns among patients with axSpA.

Methods

Data from a randomized controlled trial (NCT: 05031767) were analyzed. Patients with axSpA and low disease activity were recruited from an outpatient clinic and asked to wear a Garmin vívosmart 4 activity tracker for 1 year. The activity tracker measured steps and heart rate. Trial feasibility (eligibility, inclusion rate, and patient characteristics), technical feasibility (data recorded, tracker adherence, ie, days worn, and missing data), and operational feasibility (synchronization reminders and tracker replacements) were analyzed. Tracker adherence was calculated as the percentage of recorded minutes of the maximum possible minutes. Unsupervised hierarchical clustering was used to explore tracker wear-time patterns.

Results

Of the 160 patients screened, 75 (47%) agreed to use the tracker and 64 (85%) were analyzed (11 had insufficient data). The median activity tracker adherence over 1 year was 66% (IQR 30‐86). There was 30% missing step and 0.01% heart rate data in the physical activity dataset. A median of 18 (IQR 9‐25) reminders per patient to synchronize activity data were distributed. Analysis of wear-time patterns resulted in 3 groups: Adherent (33/64, 51% of patients), Minimal Use (17/64, 27%), and Intermittently adherent (14/64, 22%).

Conclusions

Trial feasibility was low, while technical and operational feasibility were acceptable. Only 51% of the patients were highly adherent. Activity trackers, though trendy, have low to moderate feasibility over 1 year in patients with axSpA. Automated synchronization and adherence barriers should be further explored.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Axial SpondyloarthritisExerciseFitness TrackersSpondylarthritisWearable Electronic DevicesAdultFemaleHumansMaleMiddle AgedFeasibility StudiesLongitudinal StudiesPatient ComplianceRandomized Controlled Trials as Topic

Stichwörter der Autor:innen

activity trackersaxial spondyloarthritisfeasibilityphysical activitywearables

Autor:innen und Institutionen

  • Centre for Treatment of Rheumatic and Musculoskeletal Diseases, Diakonhjemmet Hospital, Diakonveien 12, Oslo, 0370, Norway, 47 95252216.
  • Faculty of Medicine, University of Oslo, Oslo, Norway.
  • Department of Rehabilitation Science and Health Technology, OsloMet - Oslo Metropolitan University, Oslo, Norway.
  • Oslo Centre for Biostatistics & Epidemiology, Oslo University Hospital, Oslo, Norway.
  • INSERM, Institut Pierre Louis d'Epidémiologie et de Santé Publique, Sorbonne Université, Paris, France.
  • Rheumatology Department Pitié-Salpêtrière Hospital, Assistance Publique - Hôpitaux de Paris, Paris, France.

ORCID-Profile: Emil Eirik Kvernberg Thomassen, Anne Therese Tveter, Inger Jorid Berg, Eirik Klami Kristianslund, Andrew Reiner, Sarah Hakim, Laure Gossec, Gary J Macfarlane, Annette de Thurah, Nina Østerås

Zitieren

APA

Thomassen, E. E. K., Tveter, A. T., Berg, I. J., Kristianslund, E. K., Reiner, A., Hakim, S., Gossec, L., J Macfarlane, G., de Thurah, A., & Østerås, N. (2025). Feasibility of Long-Term Physical Activity Measurement With a Wearable Activity Tracker in Patients With Axial Spondyloarthritis: 1-Year Longitudinal Observational Study. JMIR Human Factors. https://doi.org/10.2196/68645

Vancouver

Thomassen EEK, Tveter AT, Berg IJ, Kristianslund EK, Reiner A, Hakim S, et al. Feasibility of Long-Term Physical Activity Measurement With a Wearable Activity Tracker in Patients With Axial Spondyloarthritis: 1-Year Longitudinal Observational Study. JMIR Human Factors. 2025. doi:10.2196/68645

BibTeX
@article{Thomassen2025,
  author = {Thomassen, Emil Eirik Kvernberg and Tveter, Anne Therese and Berg, Inger Jorid and Kristianslund, Eirik Klami and Reiner, Andrew and Hakim, Sarah and Gossec, Laure and J Macfarlane, Gary and de Thurah, Annette and Østerås, Nina},
  title = {Feasibility of Long-Term Physical Activity Measurement With a Wearable Activity Tracker in Patients With Axial Spondyloarthritis: 1-Year Longitudinal Observational Study},
  journal = {JMIR Human Factors},
  year = {2025},
  doi = {10.2196/68645}
}
Kostenlos starten →