EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Reducing Greenhouse Gas Emissions and Modifying Nitrous Oxide Delivery at Stanford: Observational, Pilot Intervention Study

Eric P Kraybill iD, David Chen iD, Saadat Khan iD, Praveen Kalra iD

JMIR Perioperative Medicine · 09.01.2025 · 8 · e64921

DOI: 10.2196/64921 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift JMIR Perioperative Medicine, online erschienen am 09.01.2025. Verfasst von Eric P Kraybill und 3 weiteren Autor:innen. Beteiligte Einrichtung: Stanford Hospital, Stanford, CA, United States. Hauptthemen laut MEDLINE: Nitrous Oxide, Greenhouse Gases. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Inhalational anesthetic agents are a major source of potent greenhouse gases in the medical sector, and reducing their emissions is a readily addressable goal. Nitrous oxide (N2O) has a long environmental half-life relative to carbon dioxide combined with a low clinical potency, leading to relatively large amounts of N2O being stored in cryogenic tanks and H cylinders for use, increasing the chance of pollution through leaks. Building on previous findings, Stanford Health Care’s (SHC’s) N2O emissions were analyzed at 2 campuses and targeted for waste reduction as a precursor to system-wide reductions.

Objective

We aimed to determine the extent of N2O pollution at SHC and subsequently whether using E-cylinders for N2O storage and delivery at the point of care in SHC’s ambulatory surgery centers could reduce system-wide emissions.

Methods

In phase 1, total SHC (Palo Alto, California) N2O purchase data for calendar year 2022 were collected and compared (volume and cost) to total Palo Alto clinical delivery data using Epic electronic health records. In phase 2, a pilot study was conducted in the 8 operating rooms of SHC campus A (Redwood City). The central N2O pipelines were disconnected, and E-cylinders were used in each operating room. E-cylinders were weighed before and after use on a weekly basis for comparison to Epic N2O delivery data over a 5-week period. In phase 3, after successful implementation, the same methodology was applied to campus B, one of 3 facilities in Palo Alto.

Results

In phase 1, total N2O purchased in 2022 was 8,217,449 L (33,201.8 lbs) at a total cost of US $63,298. Of this, only 780,882.2 L (9.5%) of N2O was delivered to patients, with 7,436,566.8 L (90.5%) or US $57,285 worth lost or wasted. In phase 2, the total mass of N2O use from E-cylinders was 7.4 lbs (1 lb N2O=247.5 L) or 1831.5 L at campus A. Epic data showed that the total N2O volume delivered was 1839.3 L (7.4 lbs). In phase 3, the total mass of N2O use from E-cylinders was 10.4 lbs or 2574 L at campus B (confirming reliability within error propagation margins). Epic data showed that the total N2O volume delivered was 2840.3 L (11.5 lbs). Over phases 2 and 3, total use for campuses A and B was less than the volume of 3 E-cylinders (1 E-cylinder=1590 L).

Conclusions

Converting N2O delivery from centralized storage to point-of-care E-cylinders dramatically reduced waste and expense with no detriment to patient care. Our results provide strong evidence for analyzing N2O storage in health care systems that rely on centralized storage, and consideration of E-cylinder implementation to reduce emissions. The reduction in N2O waste will help meet SHC’s goal of reducing scope 1 and 2 emissions by 50% before 2030.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nitrous OxideGreenhouse GasesPilot ProjectsHumansAnesthetics, InhalationCalifornia

Stichwörter der Autor:innen

anesthetic gaseselectronic health recordemissionsglobal warminggreen house gasimplementationnitrous oxidepilot studysustainability

Substanzen

Nitrous OxideGreenhouse GasesAnesthetics, Inhalation

Autor:innen und Institutionen

  • Stanford Hospital, Stanford, CA, United States.

ORCID-Profile: Eric P Kraybill, David Chen, Saadat Khan, Praveen Kalra

Zitieren

APA

Kraybill, E. P., Chen, D., Khan, S., & Kalra, P. (2025). Reducing Greenhouse Gas Emissions and Modifying Nitrous Oxide Delivery at Stanford: Observational, Pilot Intervention Study. JMIR Perioperative Medicine, 8, e64921. https://doi.org/10.2196/64921

Vancouver

Kraybill EP, Chen D, Khan S, Kalra P. Reducing Greenhouse Gas Emissions and Modifying Nitrous Oxide Delivery at Stanford: Observational, Pilot Intervention Study. JMIR Perioperative Medicine. 2025;8:e64921. doi:10.2196/64921

BibTeX
@article{Kraybill2025,
  author = {Kraybill, Eric P and Chen, David and Khan, Saadat and Kalra, Praveen},
  title = {Reducing Greenhouse Gas Emissions and Modifying Nitrous Oxide Delivery at Stanford: Observational, Pilot Intervention Study},
  journal = {JMIR Perioperative Medicine},
  year = {2025},
  volume = {8},
  pages = {e64921},
  doi = {10.2196/64921}
}