Machine Learning Approaches in High Myopia: Systematic Review and Meta-Analysis
Machine-Learning-Ansätze bei hoher Myopie: systematische Übersicht und Metaanalyse
Journal of Medical Internet Research · 03.01.2025 · 27 · e57644
DOI: 10.2196/57644 ↗Auf einen Blick
45 Studien untersuchten ML zur Diagnose von hoher Myopie, pathologischer Myopie und myopieassoziiertem Glaukom. Die diagnostische Genauigkeit war insgesamt hoch; DL schnitt bei pathologischer Myopie besser ab als konventionelles ML.
Fragestellung
Wie gut erkennen ML-Methoden in der klinischen Praxis hohe Myopie, pathologische Myopie und myopieassoziiertes Glaukom bzw. sagen eine hohe Myopie voraus?
Methode
Systematische Übersicht und Metaanalyse; Suche in PubMed, Cochrane, Embase und Web of Science bis 3. September 2023; Biasbewertung mit Prediction Model Risk of Bias Assessment Tool; bivariate Mixed-Effects-Modelle.
Ergebnisse
45 Studien, 32 in der Metaanalyse. Pathologische Myopie: SROC 0,97 (95 %-KI 0,95–0,98), Sensitivität 0,91 (95 %-KI 0,89–0,92), Spezifität 0,95 (95 %-KI 0,94–0,97). Hohe Myopie: SROC 0,98 (95 %-KI 0,96–0,99).
Einschränkungen
Es wird auf begrenzte Evidenz für die Vorhersage von hoher Myopie hingewiesen.
Schlussfolgerung der Autor:innen
ML zeigte eine sehr vielversprechende Genauigkeit für die Diagnose von hoher Myopie und pathologischer Myopie. Für die Vorhersage des zukünftigen Risikos hoher Myopie ergaben sich ebenfalls günstige Genauigkeitswerte.
Kernaussagen
- 45 Studien, 32 quantitativ ausgewertet
- Pathologische Myopie: hohe diagnostische Genauigkeit
- DL war bei pathologischer Myopie besser als nicht-DL
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Metaanalyse in der Zeitschrift Journal of Medical Internet Research, online erschienen am 03.01.2025. Verfasst von Huiyi Zuo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, First Affiliated Hospital of GuangXi Medical University, Nanning, China. Hauptthemen laut MEDLINE: Machine Learning, Myopia. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
In recent years, with the rapid development of machine learning (ML), it has gained widespread attention from researchers in clinical practice. ML models appear to demonstrate promising accuracy in the diagnosis of complex diseases, as well as in predicting disease progression and prognosis. Some studies have applied it to ophthalmology, primarily for the diagnosis of pathologic myopia and high myopia-associated glaucoma, as well as for predicting the progression of high myopia. ML-based detection still requires evidence-based validation to prove its accuracy and feasibility.
Objective
This study aims to discern the performance of ML methods in detecting high myopia and pathologic myopia in clinical practice, thereby providing evidence-based support for the future development and refinement of intelligent diagnostic or predictive tools.
Methods
PubMed, Cochrane, Embase, and Web of Science were thoroughly retrieved up to September 3, 2023. The prediction model risk of bias assessment tool was leveraged to appraise the risk of bias in the eligible studies. The meta-analysis was implemented using a bivariate mixed-effects model. In the validation set, subgroup analyses were conducted based on the ML target events (diagnosis and prediction of high myopia and diagnosis of pathological myopia and high myopia-associated glaucoma) and modeling methods.
Results
This study ultimately included 45 studies, of which 32 were used for quantitative meta-analysis. The meta-analysis results unveiled that for the diagnosis of pathologic myopia, the summary receiver operating characteristic (SROC), sensitivity, and specificity of ML were 0.97 (95% CI 0.95-0.98), 0.91 (95% CI 0.89-0.92), and 0.95 (95% CI 0.94-0.97), respectively. Specifically, deep learning (DL) showed an SROC of 0.97 (95% CI 0.95-0.98), sensitivity of 0.92 (95% CI 0.90-0.93), and specificity of 0.96 (95% CI 0.95-0.97), while conventional ML (non-DL) showed an SROC of 0.86 (95% CI 0.75-0.92), sensitivity of 0.77 (95% CI 0.69-0.84), and specificity of 0.85 (95% CI 0.75-0.92). For the diagnosis and prediction of high myopia, the SROC, sensitivity, and specificity of ML were 0.98 (95% CI 0.96-0.99), 0.94 (95% CI 0.90-0.96), and 0.94 (95% CI 0.88-0.97), respectively. For the diagnosis of high myopia-associated glaucoma, the SROC, sensitivity, and specificity of ML were 0.96 (95% CI 0.94-0.97), 0.92 (95% CI 0.85-0.96), and 0.88 (95% CI 0.67-0.96), respectively.
Conclusions
ML demonstrated highly promising accuracy in diagnosing high myopia and pathologic myopia. Moreover, based on the limited evidence available, we also found that ML appeared to have favorable accuracy in predicting the risk of developing high myopia in the future. DL can be used as a potential method for intelligent image processing and intelligent recognition, and intelligent examination tools can be developed in subsequent research to provide help for areas where medical resources are scarce. Trial Registration PROSPERO CRD42023470820; https://tinyurl.com/2xexp738
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Department, First Affiliated Hospital of GuangXi Medical University, Nanning, China.
ORCID-Profile: Huiyi Zuo, Baoyu Huang, Jian He, Liying Fang, Minli Huang
Zitieren
APA
Zuo, H., Huang, B., He, J., Fang, L., & Huang, M. (2025). Machine Learning Approaches in High Myopia: Systematic Review and Meta-Analysis. Journal of Medical Internet Research, 27, e57644. https://doi.org/10.2196/57644
Vancouver
Zuo H, Huang B, He J, Fang L, Huang M. Machine Learning Approaches in High Myopia: Systematic Review and Meta-Analysis. Journal of Medical Internet Research. 2025;27:e57644. doi:10.2196/57644
BibTeX
@article{Zuo2025,
author = {Zuo, Huiyi and Huang, Baoyu and He, Jian and Fang, Liying and Huang, Minli},
title = {Machine Learning Approaches in High Myopia: Systematic Review and Meta-Analysis},
journal = {Journal of Medical Internet Research},
year = {2025},
volume = {27},
pages = {e57644},
doi = {10.2196/57644}
}