Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review
Human Factors, Human-Centered Design und Usability sensorbasierter digitaler Gesundheitstechnologien: Scoping Review
Journal of Medical Internet Research · 15.11.2024 · 26 · e57628
DOI: 10.2196/57628 ↗Auf einen Blick
Das Review beschreibt Studien zu Human Factors, humanzentriertem Design und Usability sensorbasierter digitaler Gesundheitstechnologien. Häufig wurden nur Zufriedenheit und einfache Bedienbarkeit erfasst; andere Usability-Aspekte waren selten berichtet.
Fragestellung
Wie ist die Studienlage zu Human Factors, humanzentriertem Design und Usability sensorbasierter digitaler Gesundheitstechnologien?
Methode
Scoping Review von Studien aus 2013 bis 2023 in PubMed; extrahiert wurden Studiendesign, Stichprobe, verwendete sDHTs, Datenerhebungsmethoden und Usability-Daten.
Ergebnisse
442 Treffer, 85 Studien eingeschlossen, 83 für die Auswertung verfügbar. 164 sDHTs; 141 tragbar und 23 ambient. Zufriedenheit bei 136/164, einfache Bedienbarkeit bei 150/164; Lernbarkeit 11/164, Effizienz 4/164, Merkbarkeit 2/164.
Einschränkungen
Keine Sample-Size-Begründung in 21/83 Studien; unvollständige soziodemografische Angaben in vielen Studien.
Schlussfolgerung der Autor:innen
Die Autor:innen empfehlen, Usability breiter als nur Zufriedenheit und einfache Bedienbarkeit zu erfassen, weitere Nutzergruppen einzubeziehen und Begründungen sowie deskriptive Studiendaten vollständiger zu berichten.
Kernaussagen
- 83 von 83 Studien erfassten Daten von Zielnutzer:innen
- Zufriedenheit und einfache Bedienbarkeit dominierten die Berichte
- Lernbarkeit, Effizienz und Merkbarkeit wurden selten berichtet
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Scoping Review in der Zeitschrift Journal of Medical Internet Research, online erschienen am 15.11.2024. Verfasst von Animesh Tandon und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology and Cardiovascular Medicine, Department of Heart, Vascular, and Thoracic, Children's Institute, Cleveland Clinic Children's, C…. Hauptthemen laut MEDLINE: User-Centered Design. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 123 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Digitalisierung in der Pflege
Abstract (Originalsprache)
Background
Increasing adoption of sensor-based digital health technologies (sDHTs) in recent years has cast light on the many challenges in implementing these tools into clinical trials and patient care at scale across diverse patient populations; however, the methodological approaches taken toward sDHT usability evaluation have varied markedly.
Objective
This review aims to explore the current landscape of studies reporting data related to sDHT human factors, human-centered design, and usability, to inform our concurrent work on developing an evaluation framework for sDHT usability.
Methods
We conducted a scoping review of studies published between 2013 and 2023 and indexed in PubMed, in which data related to sDHT human factors, human-centered design, and usability were reported. Following a systematic screening process, we extracted the study design, participant sample, the sDHT or sDHTs used, the methods of data capture, and the types of usability-related data captured.
Results
Our literature search returned 442 papers, of which 85 papers were found to be eligible and 83 papers were available for data extraction and not under embargo. In total, 164 sDHTs were evaluated; 141 (86%) sDHTs were wearable tools while the remaining 23 (14%) sDHTs were ambient tools. The majority of studies (55/83, 66%) reported summative evaluations of final-design sDHTs. Almost all studies (82/83, 99%) captured data from targeted end users, but only 18 (22%) out of 83 studies captured data from additional users such as care partners or clinicians. User satisfaction and ease of use were evaluated for 83% (136/164) and 91% (150/164) of sDHTs, respectively; however, learnability, efficiency, and memorability were reported for only 11 (7%), 4 (2%), and 2 (1%) out of 164 sDHTs, respectively. A total of 14 (9%) out of 164 sDHTs were evaluated according to the extent to which users were able to understand the clinical data or other information presented to them (understandability) or the actions or tasks they should complete in response (actionability). Notable gaps in reporting included the absence of a sample size rationale (reported for 21/83, 25% of all studies and 17/55, 31% of summative studies) and incomplete sociodemographic descriptive data (complete age, sex/gender, and race/ethnicity reported for 14/83, 17% of studies).
Conclusions
Based on our findings, we suggest four actionable recommendations for future studies that will help to advance the implementation of sDHTs: (1) consider an in-depth assessment of technology usability beyond user satisfaction and ease of use, (2) expand recruitment to include important user groups such as clinicians and care partners, (3) report the rationale for key study design considerations including the sample size, and (4) provide rich descriptive statistics regarding the study sample to allow a complete understanding of generalizability to other patient populations and contexts of use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology and Cardiovascular Medicine, Department of Heart, Vascular, and Thoracic, Children's Institute, Cleveland Clinic Children's, Cleveland, OH, United States.
- Cleveland Clinic Children's Center for Artificial Intelligence, Department of Heart, Vascular, and Thoracic, Children's Institute, Cleveland Clinic Children's, Cleveland, OH, United States.
- Department of Pediatrics, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, United States.
- Healthcare Innovations Delivery, Neurology, Medical Affairs, Genentech, San Francisco, CA, United States.
- Digital Medicine Society, Boston, MA, United States.
- Koneksa Health, New York, NY, United States.
ORCID-Profile: Animesh Tandon, Bryan Cobb, Jacob Centra, Elena Izmailova, Nikolay V Manyakov, Samantha McClenahan, Smit Patel, Emre Sezgin, Srinivasan Vairavan, Bernard Vrijens, Jessie P Bakker
Zitieren
APA
Tandon, A., Cobb, B., Centra, J., Izmailova, E., Manyakov, N. V., McClenahan, S., Patel, S., Sezgin, E., Vairavan, S., Vrijens, B., Bakker, J. P., & Digital Health Measurement Collaborative Community (DATAcc) hosted by DiMe (2024). Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review. Journal of Medical Internet Research, 26, e57628. https://doi.org/10.2196/57628
Vancouver
Tandon A, Cobb B, Centra J, Izmailova E, Manyakov NV, McClenahan S, et al. Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review. Journal of Medical Internet Research. 2024;26:e57628. doi:10.2196/57628
BibTeX
@article{Tandon2024,
author = {Tandon, Animesh and Cobb, Bryan and Centra, Jacob and Izmailova, Elena and Manyakov, Nikolay V and McClenahan, Samantha and Patel, Smit and Sezgin, Emre and Vairavan, Srinivasan and Vrijens, Bernard and Bakker, Jessie P and Digital Health Measurement Collaborative Community (DATAcc) hosted by DiMe, Digital Health Measurement Collaborative Community (DATAcc) hosted by DiMe},
title = {Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review},
journal = {Journal of Medical Internet Research},
year = {2024},
volume = {26},
pages = {e57628},
doi = {10.2196/57628}
}
EUVIMED