In-Silico Works Using an Improved Hovorka Equations Model and Clinical Works on the Control of Blood Glucose Levels in People With Type 1 Diabetes: Comparison Study
JMIRx Bio · 2024
DOI: 10.2196/43662 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIRx Bio, 2024. Verfasst von Ayub Md Som und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Background
People with type 1 diabetes (T1D) depend on external insulin to regulate their blood glucose level (BGL) within the normoglycemic range between 4.0 to 7.0 mmol/L. Patients with T1D routinely conduct self-monitoring of blood glucose through finger pricks before insulin injections. An artificial pancreas is an innovative device that mimics the function of a healthy pancreas. Despite its recent advancement, the control algorithms used in an artificial pancreas are still lagging in delivering the proper insulin dosage to patients with T1D. Previous researchers attempted to improve the interrelation between parameters and variables in the original Hovorka equations model, later known as the improved Hovorka equations model; however, the improved equations model has not been tested in terms of its usability to regulate and control the BGL in a safe range for 2 or more people with T1D.
Objective
This study aimed to simulate the improved Hovorka equations model using actual patients’ data via MATLAB programming coupled with enhanced model-based predicted control and determine the optimum bolus insulin. The study then compares the performance results obtained from in-silico and clinical works.
Methods
Data from 3 patients were collected from clinic 1—Clinical Training Centre, Universiti Teknologi MARA Hospital, Sungai Buloh, Selangor—upon getting approval from the Universiti Teknologi MARA Ethics Committee. The inclusion criteria for participation were, namely having T1D, age 11-14 years, and highly dependent on insulin injection with four or more finger pricks or self-monitoring of blood glucose for BGL measurements per day. The patients with T1D typically received meals three times per day: breakfast, lunch, and dinner. A closed-loop algorithm (enhanced model-based predicted control) was used for the in-silico test, whereas an open-loop therapy was used for the clinical validation. As for the data analysis of patients, P values from a multiple linear regression were used to model the relationship between meal, insulin, and BGL.
Results
The optimum bolus insulins for patient 1 were 83.33, 33.33, and 16.67 mU/min; for patient 2 were 66.67, 50.01, and 33.33 mU/min; and for patient 3 were 100.02, 83.33, and 66.67 mU/min for breakfast, lunch, and dinner, respectively. As for the in-silico works, the percentages of time that the BGL was on target for patients 1, 2, and 3 were 79.59%, 87.76%, and 71.43%, respectively, as compared to the clinical works with
Zitieren
APA
Som, A. M., Sohadi, N. A. M., Nor, N. S. M., Ali, S. A., & Ahmad, M. A. (2024). In-Silico Works Using an Improved Hovorka Equations Model and Clinical Works on the Control of Blood Glucose Levels in People With Type 1 Diabetes: Comparison Study. JMIRx Bio. https://doi.org/10.2196/43662
Vancouver
Som AM, Sohadi NAM, Nor NSM, Ali SA, Ahmad MA. In-Silico Works Using an Improved Hovorka Equations Model and Clinical Works on the Control of Blood Glucose Levels in People With Type 1 Diabetes: Comparison Study. JMIRx Bio. 2024. doi:10.2196/43662
BibTeX
@article{Som2024,
author = {Som, Ayub Md and Sohadi, Nur Amanina Mohd and Nor, Noor Shafina Mohd and Ali, Sherif Abdulbari and Ahmad, Mohd Aizad},
title = {In-Silico Works Using an Improved Hovorka Equations Model and Clinical Works on the Control of Blood Glucose Levels in People With Type 1 Diabetes: Comparison Study},
journal = {JMIRx Bio},
year = {2024},
doi = {10.2196/43662}
}
EUVIMED