EUVIMEDEUVIMED entdecken
Open Access

Development of a Plasma Spot Assay for Detection of Fluorophore-labeled Antibodies in Mouse Imaging Studies

Norman C Peterson, Teri L Blevins, David J Ortiz

In Vivo · 2026-07 · 40 (4) · 1904-1914

DOI: 10.21873/invivo.14344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift In Vivo, online erschienen am 30.06.2026. Verfasst von Norman C Peterson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Drug Safety Research & Development, Pfizer, Inc., Bothell, WA, U.S.A.; ncpdvmphd@gmail.com. Hauptthemen laut MEDLINE: Fluorescent Dyes, Immunoconjugates, Optical Imaging, Antibodies, Monoclonal. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND/AIM: imaging of fluorescently labeled therapeutic antibodies (Ab-F) and antibody-drug conjugates (ADC-F) in mice provides an efficient approach for evaluating target-specific and nonspecific retention in tissues, inflammatory sites, and tumors. However, comparisons across compounds can be confounded by differences in pharmacokinetics, fluorophore brightness, and degree of labeling, all of which influence fluorescence intensity in regions of interest. MATERIALS AND METHODS: We developed a fluorescent plasma spot assay (FPSA) to measure relative Ab-F fluorescence in plasma and enable standardization of tissue fluorescence obtained during optical imaging studies. RESULTS: FPSA measurements were consistent with Ab-F concentration and degree-of-labeling data generated by conventional analytical methods, including immunoassay and spectrophotometry. Additionally, the FPSA was used to determine fluorophore type and DOL conditions with minimal effects on Ab-F clearance and tissue retention to minimize in-study artifacts. CONCLUSION: imaging, requires only small plasma volumes without additional processing, and allows plasma and tissue samples to be analyzed on the same instrument using matched fluorescence units. Integration of the FPSA with optimized labeling conditions provides an accurate, efficient method for comparing tissue retention of Ab-F and ADC-F in mouse optical imaging biodistribution studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesImmunoconjugatesOptical ImagingAntibodies, MonoclonalAntibodiesAnimalsMiceTissue DistributionHumans

Stichwörter der Autor:innen

Biodistributionantibody drug conjugate (ADC)biotherapeuticscancerin vivo imagingnear-infrared fluorescenceoptical imagingpharmacokinetics

Substanzen

Fluorescent DyesImmunoconjugatesAntibodies, MonoclonalAntibodies

Autor:innen und Institutionen

  • Drug Safety Research & Development, Pfizer, Inc., Bothell, WA, U.S.A.; ncpdvmphd@gmail.com.
  • Drug Safety Research & Development, Pfizer, Inc., Bothell, WA, U.S.A.
  • Pharmacokinetics, Dynamics, and Metabolism, Pfizer, Inc., Bothell, WA, U.S.A. david.ortiz3@pfizer.com.

Zitieren

APA

Peterson, N. C., Blevins, T. L., & Ortiz, D. J. (2026). Development of a Plasma Spot Assay for Detection of Fluorophore-labeled Antibodies in Mouse Imaging Studies. In Vivo, 40(4), 1904-1914. https://doi.org/10.21873/invivo.14344

Vancouver

Peterson NC, Blevins TL, Ortiz DJ. Development of a Plasma Spot Assay for Detection of Fluorophore-labeled Antibodies in Mouse Imaging Studies. In Vivo. 2026;40(4):1904-1914. doi:10.21873/invivo.14344

BibTeX
@article{Peterson2026,
  author = {Peterson, Norman C and Blevins, Teri L and Ortiz, David J},
  title = {Development of a Plasma Spot Assay for Detection of Fluorophore-labeled Antibodies in Mouse Imaging Studies},
  journal = {In Vivo},
  year = {2026},
  volume = {40},
  number = {4},
  pages = {1904--1914},
  doi = {10.21873/invivo.14344}
}
Kostenlos starten →