EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access

The Effect of Hyaluronic Acid-contained Artificial Tear on Refractive Accuracy of Cataract Surgery in Dry Eye Population: A Retrospective Cohort Study

Chia-Yi Lee, Shun-Fa Yang, Hung-Chi Chen, Jing-Yang Huang, Chao-Kai Chang

In Vivo · 2025-09 · 39 (5) · 2940-2949

DOI: 10.21873/invivo.14094 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift In Vivo, online erschienen am 28.08.2025. Verfasst von Chia-Yi Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, R.O.C. Hauptthemen laut MEDLINE: Hyaluronic Acid, Dry Eye Syndromes, Cataract Extraction, Refraction, Ocular. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND/AIM: This study aimed to investigate the association between the perioperative usage of hyaluronic acid (HA)-containing artificial tears and the refractive accuracy of cataract surgery in patients with dry eye disease (DED). PATIENTS AND METHODS: In this retrospective cohort study, patients with DED who underwent cataract surgery were categorized based on their use of HA-containing artificial tears. A total of 62 eyes were assigned to the non-HA group and 54 eyes to the HA group. The primary outcomes were the uncorrected distance visual acuity (UDVA), postoperative spherical equivalent (SE), and astigmatism assessed via vector analysis. The independent t test and the generalized linear regression were applied for the statistical analysis. RESULTS: Three months postoperatively, the UDVA in the HA group was significantly better than that in the non-HA group (p 0.05). The high axial length (AXL) significantly correlated to the higher residual SE in the HA group (p=0.001), while the low preoperative tear break-up time, high corneal astigmatism and high AXL correlated to the higher residual SE in the non-HA group (all p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hyaluronic AcidDry Eye SyndromesCataract ExtractionRefraction, OcularLubricant Eye DropsCataractHumansFemaleMaleRetrospective StudiesAgedVisual AcuityMiddle AgedTreatment OutcomeAstigmatism

Stichwörter der Autor:innen

Hyaluronic acidastigmatismcataract surgerydry eye diseasespherical equivalent

Substanzen

Hyaluronic AcidLubricant Eye Drops

Autor:innen und Institutionen

  • Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, R.O.C.
  • Nobel Eye Institute, Taipei, Taiwan, R.O.C.
  • Department of Ophthalmology, Jen-Ai Hospital Dali Branch, Taichung, Taiwan, R.O.C.
  • Department of Medical Research, Chung Shan Medical University Hospital, Taichung, Taiwan, R.O.C.
  • Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan, R.O.C.
  • Center for Tissue Engineering, Chang Gung Memorial Hospital, Linkou, Taiwan, R.O.C.

Zitieren

APA

Lee, C. Y., Yang, S. F., Chen, H. C., Huang, J. Y., & Chang, C. K. (2025). The Effect of Hyaluronic Acid-contained Artificial Tear on Refractive Accuracy of Cataract Surgery in Dry Eye Population: A Retrospective Cohort Study. In Vivo, 39(5), 2940-2949. https://doi.org/10.21873/invivo.14094

Vancouver

Lee CY, Yang SF, Chen HC, Huang JY, Chang CK. The Effect of Hyaluronic Acid-contained Artificial Tear on Refractive Accuracy of Cataract Surgery in Dry Eye Population: A Retrospective Cohort Study. In Vivo. 2025;39(5):2940-2949. doi:10.21873/invivo.14094

BibTeX
@article{Lee2025,
  author = {Lee, Chia-Yi and Yang, Shun-Fa and Chen, Hung-Chi and Huang, Jing-Yang and Chang, Chao-Kai},
  title = {The Effect of Hyaluronic Acid-contained Artificial Tear on Refractive Accuracy of Cataract Surgery in Dry Eye Population: A Retrospective Cohort Study},
  journal = {In Vivo},
  year = {2025},
  volume = {39},
  number = {5},
  pages = {2940--2949},
  doi = {10.21873/invivo.14094}
}
Kostenlos starten →