Multi-spin Redox Sensor for Electron Paramagnetic Resonance Studies of Tissue Redox State In Vivo : Validation of Data With a Conventional Spin Probe

Dessislava Lazarova, Biliana Nikolova, Zhivko Zhelev, Plamen Getsov, Milka Mileva, Rumiana Bakalova, Ichio Aoki

In Vivo · 2025

DOI: 10.21873/invivo.14069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift In Vivo, 2025. Verfasst von Dessislava Lazarova und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria. Hauptthemen laut MEDLINE: Spin Labels. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND/AIM: Redox imaging is one of the fastest growing areas in diagnostics of pathologies accompanied by redox imbalance. We describe a multi-spin redox sensor (RS) and its application for redox imaging in mice using electron paramagnetic resonance (EPR) spectroscopy. MATERIALS AND METHODS: The probe is composed of a quantum dot functionalized with a cyclodextrin shell, conjugated with nitroxide residues (TEMPO) and triphenylphosphonium to achieve intracellular delivery. The data were validated with a conventional spin probe, mito-TEMPO. Nitroxide probe (RS or mito-TEMPO) was injected intravenously in mice under anesthesia. Blood samples were collected from the tail vein at four time intervals within 2 hours and subjected immediately to analysis using EPR spectroscopy. Two hours after injection, mice were sacrificed, five organs were isolated, and tissue homogenates were prepared and subjected to EPR analysis. RESULTS: RS had the same EPR contrast and significantly higher MRI contrast compared to mito-TEMPO. RS circulated longer in the bloodstream than mito-TEMPO, with both substances undergoing reduction in the blood. The distribution of RS and mito-TEMPO in different organs was equal, except for the brain. No adverse side effects were found in mice at the selected dose. CONCLUSION: Using a non-toxic nanoparticle in the chemical structure of RS as a carrier of nitroxide residues would enhance its translational relevance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spin LabelsAnimalsElectron Spin Resonance SpectroscopyOxidation-ReductionMiceCyclic N-OxidesMagnetic Resonance ImagingQuantum DotsNitrogen OxidesTissue Distribution

Stichwörter der Autor:innen

Redox stateelectron paramagnetic resonance imagingmito-TEMPOredox sensor

Substanzen

Spin LabelsCyclic N-OxidesTEMPONitrogen Oxides

Autor:innen und Institutionen

  • Faculty of Medicine, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria.
  • Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, Bulgaria.
  • Faculty of Medicine, Trakia University, Stara Zagora, Bulgaria.
  • Faculty of Medicine, Medical University, Sofia, Bulgaria.
  • Institute of Microbiology, Bulgarian Academy of Sciences, Sofia, Bulgaria.
  • Faculty of Medicine, Sofia University "St. Kliment Ohridski", Sofia, Bulgaria; ra_bakalova@yahoo.com.

Zitieren

APA

Lazarova, D., Nikolova, B., Zhelev, Z., Getsov, P., Mileva, M., Bakalova, R., & Aoki, I. (2025). Multi-spin Redox Sensor for Electron Paramagnetic Resonance Studies of Tissue Redox State In Vivo : Validation of Data With a Conventional Spin Probe. In Vivo. https://doi.org/10.21873/invivo.14069

Vancouver

Lazarova D, Nikolova B, Zhelev Z, Getsov P, Mileva M, Bakalova R, et al. Multi-spin Redox Sensor for Electron Paramagnetic Resonance Studies of Tissue Redox State In Vivo : Validation of Data With a Conventional Spin Probe. In Vivo. 2025. doi:10.21873/invivo.14069

BibTeX
@article{Lazarova2025,
  author = {Lazarova, Dessislava and Nikolova, Biliana and Zhelev, Zhivko and Getsov, Plamen and Mileva, Milka and Bakalova, Rumiana and Aoki, Ichio},
  title = {Multi-spin Redox Sensor for Electron Paramagnetic Resonance Studies of Tissue Redox State In Vivo : Validation of Data With a Conventional Spin Probe},
  journal = {In Vivo},
  year = {2025},
  doi = {10.21873/invivo.14069}
}
Kostenlos starten →