EUVIMEDEUVIMED entdecken
Open Access

Three-dimensional Conformal Radiation Planning Study for Limited-stage Small-cell Lung Cancer

Yukinori Okada, Tatsuhiko Zama, Tomohiro Itonaga, Ryuji Mikami, Mitsuru Okubo, Shinji Sugahara, Shiho Wada, Tsubasa Kawamoto, Masanori Ishida, Motoki Nakai, Koichiro Abe, Mana Yoshimura und 3 weitere

Cancer Diagnosis & Prognosis · 01.03.2026 · 6 (2) · 265-272

DOI: 10.21873/cdp.10526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cancer Diagnosis & Prognosis, online erschienen am 01.03.2026. Verfasst von Yukinori Okada und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Tokyo Medical University, Tokyo, Japan. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aim: To carry out a preliminary study to evaluate the dose distribution variation between the analytical anisotropic algorithm (AAA) and the Boltzmann transport equation, and between point and volume prescriptions in three-dimensional conformal radiation for limited-stage small-cell lung cancer. Patients and Methods: We retrospectively selected patients with limited-stage small-cell lung cancer who received radiotherapy alone or chemoradiotherapy. Gross tumor volume (GTV), clinical target volume (CTV), and planning target volume (PTV) were evaluated. Dose evaluation was performed for PTV, with AAA as point prescription, AAA as 50% prescription of PTV, Boltzmann transport equation as point prescription, and Boltzmann transport equation as 50% prescription of PTV. Results: A total of 22 patients (15 males, 7 females; mean age=63.4 years) were included. The mean radiation doses for AAA/point AAA/D50, Boltzmann transport/point, and Boltzmann transport/D50 methods were 99.97±1.5%, 102.1±1.2%, 100.8±1.2%, and 101.3±1.3% to the GTV; 98.4±2.1%, 100.4±0.5%, 99.6±1.9%, 100.1±1.0% to the CTV; and 96.7±2.5%, 97.4±4.6%, 97.6±2.3%, 98.3±0.8% to the PTV, respectively. For AAA/point, AAA/D50, Boltzmann transport/point, and Boltzmann transport/D50 prescription methods, the correlation between the GTV (102.5±107.8 ml) and mean dose to the GTV was 0.23 (p=0.4), −0.476 (p=0.04), 0.00 (p=0.97), −0.79 (p

Schlagwörter

Stichwörter der Autor:innen

Boltzmann transportLimited-stage small-cell canceranalytical anisotropic algorithmchemotherapyradiationthree-dimensional conformal radiation

Autor:innen und Institutionen

  • Department of Radiology, Tokyo Medical University, Tokyo, Japan.
  • Department of Radiation Therapy, Tokyo Medical University Hospital, Tokyo, Japan.

Zitieren

APA

Okada, Y., Zama, T., Itonaga, T., Mikami, R., Okubo, M., Sugahara, S., Wada, S., Kawamoto, T., Ishida, M., Nakai, M., Abe, K., Yoshimura, M., Kodama, T., Kurooka, M., & Saito, K. (2026). Three-dimensional Conformal Radiation Planning Study for Limited-stage Small-cell Lung Cancer. Cancer Diagnosis & Prognosis, 6(2), 265-272. https://doi.org/10.21873/cdp.10526

Vancouver

Okada Y, Zama T, Itonaga T, Mikami R, Okubo M, Sugahara S, et al. Three-dimensional Conformal Radiation Planning Study for Limited-stage Small-cell Lung Cancer. Cancer Diagnosis & Prognosis. 2026;6(2):265-272. doi:10.21873/cdp.10526

BibTeX
@article{Okada2026,
  author = {Okada, Yukinori and Zama, Tatsuhiko and Itonaga, Tomohiro and Mikami, Ryuji and Okubo, Mitsuru and Sugahara, Shinji and Wada, Shiho and Kawamoto, Tsubasa and Ishida, Masanori and Nakai, Motoki and Abe, Koichiro and Yoshimura, Mana and Kodama, Takashi and Kurooka, Masahiko and Saito, Kazuhiro},
  title = {Three-dimensional Conformal Radiation Planning Study for Limited-stage Small-cell Lung Cancer},
  journal = {Cancer Diagnosis & Prognosis},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {265--272},
  doi = {10.21873/cdp.10526}
}
Kostenlos starten →