EUVIMEDEUVIMED entdecken
Crossref

Towards Personalization of Planning Target Volume Margins Fitted to the Abdominal Adiposity in Localized Prostate Cancer Patients Receiving Definitive or Adjuvant/Salvage Radiotherapy: Suggestive Data from an ExacTrac vs . CBCT Comparison

Gianluca Ferini, Valentina Zagardo, Vito Valenti, Dario Aiello, Manuela Federico, Ivan Fazio, Mandara Muralidhar Harikar, Valentina Anna Marchese, Salvatore Ivan Illari, Anna Viola, Emanuele Martorana

Anticancer Research · 2023

DOI: 10.21873/anticanres.16597 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Anticancer Research, 2023. Verfasst von Gianluca Ferini und 10 weiteren Autor:innen. Beteiligte Einrichtung: REM Radioterapia srl, Viagrande, Italy; gianluca.ferini@grupposamed.com. Hauptthemen laut MEDLINE: Spiral Cone-Beam Computed Tomography, Prostatic Neoplasms. Die Arbeit wurde bisher 9-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND/AIM: This study aimed to assess whether the patient's abdominal adiposity affects the performance of the Exactrac imaging system compared to the cone beam computed tomography (CBCT)-based setup, which was used as the reference positioning for the image-guided radiotherapy (IGRT) delivery to patients with localized prostate cancer. PATIENTS AND METHODS: The daily positionings of patients with localized prostate cancer undergoing definitive or adjuvant/salvage radiotherapy (RT) were analyzed. The abdominal fat areas and pelvic incidence angle were determined on the CT simulation for each patient. A couple of ExacTrac images and a CBCT were acquired daily to verify the patient setup. We recorded every daily set of the three residual translational errors detected on the CBCT after the ExacTrac-based setup. These sets were clustered within three different thresholds (0.1 mm, 0.2 mm, and 0.3 mm), for each of which the influence of adipose tissues on Exactrac accuracy was assessed as the percentage of sub-threshold displacements as the fat parameters varied. A full bladder and empty rectum preparation protocol was adopted as much as possible. RESULTS: From the assessment of 1,770 daily positionings in 55 patients (38 definitive RT, 17 adjuvant/salvage RT), a good agreement between ExacTrac and CBCT could be inferred, which was quite robust against slight variations in the bladder and rectal filling, and the presence or not of the prostate. The percentages of above-threshold corrections increased with increasing abdominal fat, which therefore seemed to reduce the ExacTrac accuracy. This might be influenced by any intrafraction prostate displacement, likely induced by abdominal respiratory movements, and are more pronounced among overweight men. CONCLUSION: Our results promote the CBCT use over ExacTrac for IGRT of overweight patients with localized prostate cancer, while calling for attention to the probable need for personalization of planning target volume margins depending on the patient's body habitus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spiral Cone-Beam Computed TomographyProstatic NeoplasmsMaleHumansAdiposityOverweightProstateSeizures

Stichwörter der Autor:innen

ExacTracImage-guided radiotherapycone beam computed tomographyfat tissuespersonalized radiation therapyprostate cancer

Autor:innen und Institutionen

  • REM Radioterapia srl, Viagrande, Italy; gianluca.ferini@grupposamed.com.
  • REM Radioterapia srl, Viagrande, Italy.
  • Radiotherapy Unit, Casa di Cura Macchiarella, Palermo, Italy.
  • Cannizzaro Hospital, Catania, Italy.
  • Fondazione Istituto Oncologico del Mediterraneo, Viagrande, Italy.
  • Istituto Oncologico del Mediterraneo, Viagrande, Italy.

Zitieren

APA

Ferini, G., Zagardo, V., Valenti, V., Aiello, D., Federico, M., Fazio, I., Harikar, M. M., Marchese, V. A., Illari, S. I., Viola, A., & Martorana, E. (2023). Towards Personalization of Planning Target Volume Margins Fitted to the Abdominal Adiposity in Localized Prostate Cancer Patients Receiving Definitive or Adjuvant/Salvage Radiotherapy: Suggestive Data from an ExacTrac vs . CBCT Comparison. Anticancer Research. https://doi.org/10.21873/anticanres.16597

Vancouver

Ferini G, Zagardo V, Valenti V, Aiello D, Federico M, Fazio I, et al. Towards Personalization of Planning Target Volume Margins Fitted to the Abdominal Adiposity in Localized Prostate Cancer Patients Receiving Definitive or Adjuvant/Salvage Radiotherapy: Suggestive Data from an ExacTrac vs . CBCT Comparison. Anticancer Research. 2023. doi:10.21873/anticanres.16597

BibTeX
@article{Ferini2023,
  author = {Ferini, Gianluca and Zagardo, Valentina and Valenti, Vito and Aiello, Dario and Federico, Manuela and Fazio, Ivan and Harikar, Mandara Muralidhar and Marchese, Valentina Anna and Illari, Salvatore Ivan and Viola, Anna and Martorana, Emanuele},
  title = {Towards Personalization of Planning Target Volume Margins Fitted to the Abdominal Adiposity in Localized Prostate Cancer Patients Receiving Definitive or Adjuvant/Salvage Radiotherapy: Suggestive Data from an ExacTrac vs . CBCT Comparison},
  journal = {Anticancer Research},
  year = {2023},
  doi = {10.21873/anticanres.16597}
}
Kostenlos starten →