EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseVergleichsstudie

Accuracy of conventional versus additive cast-fabrication in implant prosthodontics: A systematic review and meta-analysis of in vitro studies

Boldizsár Vánkos, Xinyi Qian, Kata Kelemen, Krisztina Mikulás, Tamás Kói, Réka Tóth, Gergely Agócs, Gábor Varga, Péter Hegyi, Péter Hermann, Barbara Kispélyi

Journal of Prosthodontic Research · 2024

DOI: 10.2186/jpr.jpr_d_23_00261 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Prosthodontic Research, 2024. Verfasst von Boldizsár Vánkos und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Semmelweis University, Budapest, Hungary. Hauptthemen laut MEDLINE: Dental Implants, Dental Prosthesis Design, Dental Casting Technique, Prosthodontics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Additive cast-fabrication has yet to be used as commonly in implant prosthodontics as conventional methods. This review aimed to investigate the accuracy of additive cast-fabrication in implant prosthodontics. STUDY SELECTION: The study protocol was registered in the PROSPERO database (CRD42022374972). Reporting was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines, following the Cochrane Handbook. Two-arm interventional studies that matched the PICO were included (Population: dental typodonts with implants, Intervention: additive cast-fabrication, Comparator: conventional cast-fabrication, Outcome: positional deviations). A systematic search was conducted in three databases: PubMed (MEDLINE), EMBASE, and the Cochrane Library (CENTRAL). RESULTS: Seven papers were included in the analysis of horizontal, vertical, and root mean square (RMS) deviations. No significant differences were observed between groups. The overall vertical mean deviation of the intervention group was -4.15 µm [-24.88; 16.57], and the pooled mean absolute deviation was 22.43 µm [8.33; 36.54]. In the control group, these values were 19.67 µm [-32.71; 72.04] and 24.62 µm [0.00; 59.42], respectively. The overall horizontal mean deviation in the intervention group was 21.29 µm [-77.10; 119.68], and the pooled mean absolute deviation was 26.96 µm [0.00; 70.81]. In the control group, the overall mean was 1.45 µm [-32.26; 35.15] and the pooled mean absolute deviation was 25.05 µm [9.08; 41.01]. The mean RMS was only slightly larger in the intervention group, with the value of 14.74 µm [-107.26; 136.74]. CONCLUSIONS: Additive cast-fabrication is as accurate as the conventional method for the position of implant analogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsDental Prosthesis DesignDental Casting TechniqueProsthodonticsHumans

Stichwörter der Autor:innen

Dental Casting techniqueDental implantationDental impression techniqueModelsProsthodontics

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
  • Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
  • Department of Stochastics, Institute of Mathematics, Budapest University of Technology and Economics, Budapest, Hungary.
  • Department of Oral Biology, Semmelweis University, Budapest, Hungary.
  • Institute of Pancreatic Diseases, Semmelweis University, Budapest, Hungary.
  • Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary.

Zitieren

APA

Vánkos, B., Qian, X., Kelemen, K., Mikulás, K., Kói, T., Tóth, R., Agócs, G., Varga, G., Hegyi, P., Hermann, P., & Kispélyi, B. (2024). Accuracy of conventional versus additive cast-fabrication in implant prosthodontics: A systematic review and meta-analysis of in vitro studies. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_23_00261

Vancouver

Vánkos B, Qian X, Kelemen K, Mikulás K, Kói T, Tóth R, et al. Accuracy of conventional versus additive cast-fabrication in implant prosthodontics: A systematic review and meta-analysis of in vitro studies. Journal of Prosthodontic Research. 2024. doi:10.2186/jpr.jpr_d_23_00261

BibTeX
@article{Vnkos2024,
  author = {Vánkos, Boldizsár and Qian, Xinyi and Kelemen, Kata and Mikulás, Krisztina and Kói, Tamás and Tóth, Réka and Agócs, Gergely and Varga, Gábor and Hegyi, Péter and Hermann, Péter and Kispélyi, Barbara},
  title = {Accuracy of conventional versus additive cast-fabrication in implant prosthodontics: A systematic review and meta-analysis of in vitro studies},
  journal = {Journal of Prosthodontic Research},
  year = {2024},
  doi = {10.2186/jpr.jpr_d_23_00261}
}
Kostenlos starten →