EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment

Young Kwon Han, Kyoungwon Lee

Audiology and Speech Research · 2020

DOI: 10.21848/asr.200010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Audiology and Speech Research, 2020. Verfasst von Young Kwon Han und 1 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Several studies have reported the differences between Korean and other countries’ speech in long-term average speech spectrum (LTASS) and band importance function. Authors tried to identify the conversational speech level, the resulting spectrum, and the LTASS for Korean. The purpose of this study was to support the production of a Korean-type hearing aid fitting formula to effectively improve the sound quality of hearing aids and the communication abilities with hearing aids, and to standardize the sound stimuli required to measure the performance of hearing aids.

Methods

A total of 73 participants with normal hearing and with no specific voice and language deficits was voluntarily recruited from capital, Gyeongsang and Jeolla areas. The conversational speech level was measured by vocalizing ‘soft,’ ‘moderate,’ ‘raised,’ and ‘loud’ at a distance of 1.0 m from the speaker. And LTASS was measured by vocalizing it at a distance of 0.2 m from the speaker.

Results

There was a difference in the mean of males and females in the conversation level, but no significant regional differences were shown. The conversational speech level corresponding to 30th, 65th, and 99th percentiles was 59.67, 64.74, and 79.07 dB sound pressure level, respectively. And the speech spectrum of 30th, 65th, and 99th percentile and LTASS showed in different forms from the international speech test signal.

Conclusion

The results of this study should help to calculate the Korean type hearing aid fitting formula and should be used as the basic data to determine the characteristics of the sound stimuli when measuring the performance of the hearing aid.

Zitieren

APA

Han, Y. K., & Lee, K. (2020). A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment. Audiology and Speech Research. https://doi.org/10.21848/asr.200010

Vancouver

Han YK, Lee K. A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment. Audiology and Speech Research. 2020. doi:10.21848/asr.200010

BibTeX
@article{Han2020,
  author = {Han, Young Kwon and Lee, Kyoungwon},
  title = {A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment},
  journal = {Audiology and Speech Research},
  year = {2020},
  doi = {10.21848/asr.200010}
}
Kostenlos starten →