Effect of Heparin Contaminated with Oversulfated Chondroitin Sulfate on the Collection and Analysis of Plasma~!2009-10-12~!2010-02-04~!2010-03-25~!
The Open Clinical Chemistry Journal · 2010
DOI: 10.2174/1874241601003010005 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Open Clinical Chemistry Journal, 2010. Verfasst von Tracey Bosworth und 12 weiteren Autor:innen.
Abstract (Originalsprache)
Oversulfated chrondroitin sulfate (OSCS) was recently identified as a contaminant of heparin and was associated with serious adverse events in patients treated with heparin.Because heparin is a common component of blood collection tubes, we tested the effect of OSCS on the laboratory analysis of plasma.Blood from healthy volunteers (N=50) was collected into tubes containing various mixtures of heparin and OSCS.Samples were inspected for microclots and were analyzed for a panel of 28 routine laboratory tests.No microclots were observed in tubes that contained only heparin but were detected in 18%, 88% and 76% of plasma samples containing 5%, 15%, 20% OSCS (%weight relative to heparin), respectively.OSCS at the highest dose (20%) caused a systematic bias for the following 6 tests: Lactate Dehydrogenase: 18% (12% to 24%); Triiodothyronine: -5.7% (-8.1% to -3.3%); Potassium: -2.8% (-4.2% to -1.4%);Total Protein: 2.5% (1.4% to 3.6%); Chloride: -1.4% (-1.8% to -1.0%) and Uric Acid: 1% (0.5% to 1.4%).In summary, OSCS contamination of heparin was found to potentially affect the anticoagulation of plasma and the analytical performance of several routine clinical laboratory tests.
Zitieren
APA
Bosworth, T., Chan, Y., Nguyen, T., Gutman, S., Gutierrez, A., Kalush, F., Gwise, T., Pollack, S., Guo, J., Patwardhan, D., Buhse, L., Reepmeyer, J. C., & Remaley, A. T. (2010). Effect of Heparin Contaminated with Oversulfated Chondroitin Sulfate on the Collection and Analysis of Plasma~!2009-10-12~!2010-02-04~!2010-03-25~!. The Open Clinical Chemistry Journal. https://doi.org/10.2174/1874241601003010005
Vancouver
Bosworth T, Chan Y, Nguyen T, Gutman S, Gutierrez A, Kalush F, et al. Effect of Heparin Contaminated with Oversulfated Chondroitin Sulfate on the Collection and Analysis of Plasma~!2009-10-12~!2010-02-04~!2010-03-25~!. The Open Clinical Chemistry Journal. 2010. doi:10.2174/1874241601003010005
BibTeX
@article{Bosworth2010,
author = {Bosworth, Tracey and Chan, Yung and Nguyen, Tan and Gutman, Steve and Gutierrez, Alberto and Kalush, Francis and Gwise, Thomas and Pollack, Steven and Guo, Ji and Patwardhan, Dinesh and Buhse, Lucinda and Reepmeyer, John C. and Remaley, Alan T.},
title = {Effect of Heparin Contaminated with Oversulfated Chondroitin Sulfate on the Collection and Analysis of Plasma~!2009-10-12~!2010-02-04~!2010-03-25~!},
journal = {The Open Clinical Chemistry Journal},
year = {2010},
doi = {10.2174/1874241601003010005}
}
EUVIMED