EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Intraobserver and Interobserver Reproducibility for Radial, Circumferential and Longitudinal Strain Echocardiography

R Leischik, B Dworrak, K Hensel

The Open Cardiovascular Medicine Journal · 17.10.2014 · 8 (1) · 102-109

DOI: 10.2174/1874192401408010102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Open Cardiovascular Medicine Journal, erschienen am 17.10.2014. Verfasst von R Leischik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Section Prevention and Sports Medicine, Witten/Herdecke University, Faculty of Health, School of Medicine, Hagen, Germany. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Strain echocardiography (StE) promises to be a new tool for quantitative assessment of cardiac function. Analysis of intra- and interobserver reliability is an important aspect in the process of developing these novel techniques from theory to the implementation into daily routine diagnostics.The purpose of the study was to estimate reliability of the segmental StE.

Methods

Left ventricular strain analysis for radial strain (RS), circumferential strain (CS) and longitudinal strain (LS) was performed in 21 healthy volunteers. RS and CS values were obtained in the parasternal short axis at the level of the papillary muscles. LS values were determined in the apical 2-, 3- and 4-chamber views. Cine-loops were recorded and quantitative analyses were conducted on an off-line workstation.

Results

Intraobserver reproducibility was highest using LS in the 4-chamber view (9 ± 13.6 % mean deviation, rho = 0.624, p = 0.003), followed by CS (13.3 ± 8.3 %, rho = 0.406, p = 0.068) and lowest in RS (26.3 ± 30.1 %, rho = 0.391, p = 0.080). Interobserver analyses of LS derived from 3-chamber view showed lowest deviation (11.9 ± 9.5 %, rho = 0.513, p = 0.017), followed by CS (15.2 ± 12.0 %, 0.263, p = 0.249) and the least consistent measurements in RS (35.9 ± 46.3 %, rho 0.382, p = 0.088).

Conclusion

This study shows that the clinical utility of StE depends on the regional differences of LV wall motion and image quality. LS-values showed promising intra- and interobserver reproducibility values. For quantitative follow-up studies LS should be preferred.

Schlagwörter

Stichwörter der Autor:innen

Interobserver-varabilityintraobserver-variabilityreproducibilitystrain.

Autor:innen und Institutionen

  • Department of Cardiology, Section Prevention and Sports Medicine, Witten/Herdecke University, Faculty of Health, School of Medicine, Hagen, Germany.
  • Helios Children Hospital, Witten/Herdecke University, Faculty of Health, School of Medicine, Wuppertal, Germany.

Zitieren

APA

Leischik, R., Dworrak, B., & Hensel, K. (2014). Intraobserver and Interobserver Reproducibility for Radial, Circumferential and Longitudinal Strain Echocardiography. The Open Cardiovascular Medicine Journal, 8(1), 102-109. https://doi.org/10.2174/1874192401408010102

Vancouver

Leischik R, Dworrak B, Hensel K. Intraobserver and Interobserver Reproducibility for Radial, Circumferential and Longitudinal Strain Echocardiography. The Open Cardiovascular Medicine Journal. 2014;8(1):102-109. doi:10.2174/1874192401408010102

BibTeX
@article{Leischik2014,
  author = {Leischik, R and Dworrak, B and Hensel, K},
  title = {Intraobserver and Interobserver Reproducibility for Radial, Circumferential and Longitudinal Strain Echocardiography},
  journal = {The Open Cardiovascular Medicine Journal},
  year = {2014},
  volume = {8},
  number = {1},
  pages = {102--109},
  doi = {10.2174/1874192401408010102}
}
Kostenlos starten →