Brine recovery from reverse osmosis effluents using an automatic temperature control system: salt crystallization

Jumanne Mayige Shimba iD, Oscar Ezekiel Njau, Juma Selemani, Karoli Nicholaus Njau

Water Science & Technology · 2025

DOI: 10.2166/wst.2025.047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Science & Technology, 2025. Verfasst von Jumanne Mayige Shimba und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials, Energy, Water, and Environmental Sciences, Nelson Mandela African Institution of Science and Technology (NM-AIST), P.O. Box 447,…. Hauptthemen laut MEDLINE: Waste Disposal, Fluid, Water Purification. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The improper brine effluent disposal from the reverse osmosis (RO) process of the industry and mining sites poses various environmental problems including impaired soil ability to produce crops, difficulties for breeding and migrating birds. Various treatment methods reported to provide a short-term solution in which separation of the mixed salt byproducts remains a great challenge. The present study aimed at assessing the performance of locally available automatic temperature control (ATC) system to recover brine from RO effluents through salt crystallization. Laboratory trials via batch experiment containing individual and mixed samples of NaCl·2H2O, Na2SO4·10H2O, and Na2CO3·10H2O were conducted to evaluate the influence of freezing temperature, concentration, and contact time. The maximum recovery efficiencies of 85.3% (NaCl·2H2O), 93.3% (Na2SO4·10H2O), and 32.0% (Na2CO3·10H2O) of the individual samples were achieved at 72 h (−26 °C), 96 h (–10 °C), and 2 h (–2 °C), respectively. For mixed samples at −10 °C and 3 h in 50 mL, 29.37 g (65.27%) were recovered with ionic constituents such as Na+ (34.1%), Cl− (1.6%), SO42− (11.3%), CO32− (32.4%), and impurities (20.57%). The findings of this study suggested that ATC could be used as an alternative technology for brine recovery from RO process of industry and mining operation sites.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Waste Disposal, FluidWater PurificationSaltsOsmosisCrystallizationTemperature

Stichwörter der Autor:innen

automatic temperature controlbrinefreezing crystallizationreverse osmosissalt crystals

Substanzen

Saltsbrine

Autor:innen und Institutionen

  • School of Materials, Energy, Water, and Environmental Sciences, Nelson Mandela African Institution of Science and Technology (NM-AIST), P.O. Box 447, Arusha, Tanzania.
  • Tanzania Gemmological Centre (TGC), P.O. Box 119, Arusha, Tanzania E-mail: mayigej@nm-aist.ac.tz.

ORCID-Profile: Jumanne Mayige Shimba

Zitieren

APA

Shimba, J. M., Njau, O. E., Selemani, J., & Njau, K. N. (2025). Brine recovery from reverse osmosis effluents using an automatic temperature control system: salt crystallization. Water Science & Technology. https://doi.org/10.2166/wst.2025.047

Vancouver

Shimba JM, Njau OE, Selemani J, Njau KN. Brine recovery from reverse osmosis effluents using an automatic temperature control system: salt crystallization. Water Science & Technology. 2025. doi:10.2166/wst.2025.047

BibTeX
@article{Shimba2025,
  author = {Shimba, Jumanne Mayige and Njau, Oscar Ezekiel and Selemani, Juma and Njau, Karoli Nicholaus},
  title = {Brine recovery from reverse osmosis effluents using an automatic temperature control system: salt crystallization},
  journal = {Water Science & Technology},
  year = {2025},
  doi = {10.2166/wst.2025.047}
}
Kostenlos starten →