EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Stormwater runoff pollution control performance of permeable concrete pavement and constructed wetland combined system: toward on-site reuse

Jinhui Zhao iD, Lisha Shu, Mengke Wu, Jiabi Han, Shuyu Luo, Jixian Tang

Water Science & Technology · 15.09.2023 · 88 (6) · 1345-1357

DOI: 10.2166/wst.2023.273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Science & Technology, online erschienen am 28.08.2023. Verfasst von Jinhui Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: L.S. contributed equally to the work with J.Z. and should be considered a co-first author. E-mail: zhaojh@njtech.edu.cn. Hauptthemen laut MEDLINE: Wetlands, Environmental Pollutants. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jiangsu Provincial Department of Housing and Urban-Rural Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Urban waterlogging and the deterioration of receiving water quality caused by stormwater runoff have become increasingly significant problems. Based on the concept of combining grey and green infrastructure, a combined permeable concrete pavement (PCP) and constructed wetland (CW) system has been developed to treat stormwater runoff and enable on-site reuse. The results showed that the removal rate of suspended solids (SS) by PCP ranged from 96.61 to 99.20%; however, the chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations in the effluent did not meet the standards required for rainwater reuse. For the combined PCP-CW system, the removal rates of COD, TN and TP by the CW were 48.45–75.12%, 47.26–53.05%, and 59.04–75.28%, respectively, under different hydraulic loading (HL) rates; thus, the effluent TN concentrations did not consistently meet the reuse standards. Further optimization of aeration in different parts of the CW revealed that aeration in the middle and front sections of the wetland had the most significant effect on pollutant removal, under which the TN concentrations in the effluent met the standard required for reuse. The effluent from the combined PCP-CW system was able to fully meet the stormwater reuse standards under these optimized conditions, and the reuse of urban stormwater runoff can therefore be realized.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WetlandsEnvironmental PollutantsNitrogenPhosphorusWater Quality

Substanzen

Environmental PollutantsNitrogenPhosphorus

Autor:innen und Institutionen

  • L.S. contributed equally to the work with J.Z. and should be considered a co-first author. E-mail: zhaojh@njtech.edu.cn.

ORCID-Profile: Jinhui Zhao

Förderung

  • Jiangsu Provincial Department of Housing and Urban-Rural Development

Zitieren

APA

Zhao, J., Shu, L., Wu, M., Han, J., Luo, S., & Tang, J. (2023). Stormwater runoff pollution control performance of permeable concrete pavement and constructed wetland combined system: toward on-site reuse. Water Science & Technology, 88(6), 1345-1357. https://doi.org/10.2166/wst.2023.273

Vancouver

Zhao J, Shu L, Wu M, Han J, Luo S, Tang J. Stormwater runoff pollution control performance of permeable concrete pavement and constructed wetland combined system: toward on-site reuse. Water Science & Technology. 2023;88(6):1345-1357. doi:10.2166/wst.2023.273

BibTeX
@article{Zhao2023,
  author = {Zhao, Jinhui and Shu, Lisha and Wu, Mengke and Han, Jiabi and Luo, Shuyu and Tang, Jixian},
  title = {Stormwater runoff pollution control performance of permeable concrete pavement and constructed wetland combined system: toward on-site reuse},
  journal = {Water Science & Technology},
  year = {2023},
  volume = {88},
  number = {6},
  pages = {1345--1357},
  doi = {10.2166/wst.2023.273}
}
Kostenlos starten →