EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

What is the best design approach for estimating effluent concentrations from horizontal flow treatment wetlands: the use of volumetric ( k V) or areal ( k A) removal rate coefficients?

Marcos von Sperling iD, Scott D Wallace, Jaime Nivala iD

Water Science & Technology · 15.07.2023 · 88 (2) · 502-515

DOI: 10.2166/wst.2023.221 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Science & Technology, online erschienen am 14.07.2023. Verfasst von Marcos von Sperling und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais (UFMG), Belo Horizonte, Brazil E-mail: jaime.nivala@inrae.fr. Hauptthemen laut MEDLINE: Waste Disposal, Fluid, Wetlands. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effluent concentrations from horizontal flow (HF) treatment wetlands can be estimated by using the Tanks-In-Series model for describing hydraulics and first-order removal rate coefficients for describing pollutant removal. In the design of conventional wastewater treatment plants, volumetric removal rate coefficients (kV) are traditionally used in conjunction with the theoretical hydraulic retention time. Areal removal rate coefficients (kA) coupled with the applied areal hydraulic loading rate are widely used in the literature. Despite this, supporting evidence of its appropriateness is scarce in the literature. The objective of this study is to investigate the adequacy of both approaches by analyzing the influence of liquid depth on kV and kA. Data from 74 HF wetlands were collected, covering biochemical oxygen demand and chemical oxygen demand, and diverse types of influents (raw sewage and primary, secondary and tertiary effluents). For these conditions, kV decreased with depth of the wetland system. Regression analyses between depth and removal rate coefficients were performed, and the equations indicated that kV was approximately related to the inverse of depth, while kA was almost independent of depth. These findings endorse the utilization of the areal-based approach for design purposes. The volumetric-based approach can also be used, but the value of kV must be provided together with the depth being considered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Waste Disposal, FluidWetlandsWastewaterSewageBiological Oxygen Demand AnalysisNitrogen

Substanzen

WastewaterSewageNitrogen

Autor:innen und Institutionen

  • Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais (UFMG), Belo Horizonte, Brazil E-mail: jaime.nivala@inrae.fr.
  • Naturally Wallace Consulting, Pilot Mountain, NC 27041, USA.
  • INRAE, UR REVERSAAL, 5 rue de la Doua, CS 20244, Villeurbanne 69625, France.

ORCID-Profile: Marcos von Sperling, Jaime Nivala

Zitieren

APA

von Sperling, M., Wallace, S. D., & Nivala, J. (2023). What is the best design approach for estimating effluent concentrations from horizontal flow treatment wetlands: the use of volumetric ( k V) or areal ( k A) removal rate coefficients?. Water Science & Technology, 88(2), 502-515. https://doi.org/10.2166/wst.2023.221

Vancouver

von Sperling M, Wallace SD, Nivala J. What is the best design approach for estimating effluent concentrations from horizontal flow treatment wetlands: the use of volumetric ( k V) or areal ( k A) removal rate coefficients?. Water Science & Technology. 2023;88(2):502-515. doi:10.2166/wst.2023.221

BibTeX
@article{vonSperling2023,
  author = {von Sperling, Marcos and Wallace, Scott D and Nivala, Jaime},
  title = {What is the best design approach for estimating effluent concentrations from horizontal flow treatment wetlands: the use of volumetric ( k V) or areal ( k A) removal rate coefficients?},
  journal = {Water Science & Technology},
  year = {2023},
  volume = {88},
  number = {2},
  pages = {502--515},
  doi = {10.2166/wst.2023.221}
}
Kostenlos starten →