EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of surface hydrophobicity on the removal of F-specific RNA phages from reclaimed water by coagulation and ceramic membrane microfiltration

Midori Yasui, Luisa Ikner, Takashi Yonetani, Miaomiao Liu, Hiroyuki Katayama

Water Science & Technology · 2023

DOI: 10.2166/wst.2023.133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Science & Technology, 2023. Verfasst von Midori Yasui und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urban Engineering, The University of Tokyo, Tokyo, Japan E-mail: yasui@env.t.u-tokyo.ac.jp. Hauptthemen laut MEDLINE: RNA Phages, Water Purification, Viruses. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microfiltration (MF) has been widely adopted as an advanced treatment process to reduce suspended solids and turbidity in treated wastewater effluents designated for potable reuse. Although microfilter pores are much larger than viruses, the addition of a coagulant upstream of a microfilter system can achieve stable virus removal. Ceramic membranes have a narrow pore size distribution to achieve the high removal of contaminants. This study aims to evaluate virus log reduction using bench-scale coagulation and ceramic membrane MF. To investigate the effects of differences in net surface hydrophobicity, 18 sewage-derived F-specific RNA phages (FRNAPHs) were used for batch hydrophobicity and coagulation–MF tests. The capability of bench-scale coagulation and ceramic membrane MF under continuous automated long-term operation was tested to remove the lab reference strain MS2 and three selected FRNAPH isolates which varied by surface property. Median virus log reduction values (LRVs) exceeding 6.2 were obtained for all three isolates and MS2. Although coagulation and hydrophobicity were positively correlated, the virus isolate demonstrating the lowest level of hydrophobicity and coagulation (genogroup I) still exhibited a high LRV. Thus, coagulation and ceramic membrane MF systems may serve as viable options for virus removal during water reclamation and advanced treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RNA PhagesWater PurificationVirusesUltrafiltrationCeramicsMembranes, Artificial

Substanzen

Membranes, Artificial

Autor:innen und Institutionen

  • Department of Urban Engineering, The University of Tokyo, Tokyo, Japan E-mail: yasui@env.t.u-tokyo.ac.jp.
  • Department of Environmental Science, The University of Arizona, Tucson, AZ, USA.
  • Metawater Co. Ltd, Tokyo, Japan.

Zitieren

APA

Yasui, M., Ikner, L., Yonetani, T., Liu, M., & Katayama, H. (2023). Effects of surface hydrophobicity on the removal of F-specific RNA phages from reclaimed water by coagulation and ceramic membrane microfiltration. Water Science & Technology. https://doi.org/10.2166/wst.2023.133

Vancouver

Yasui M, Ikner L, Yonetani T, Liu M, Katayama H. Effects of surface hydrophobicity on the removal of F-specific RNA phages from reclaimed water by coagulation and ceramic membrane microfiltration. Water Science & Technology. 2023. doi:10.2166/wst.2023.133

BibTeX
@article{Yasui2023,
  author = {Yasui, Midori and Ikner, Luisa and Yonetani, Takashi and Liu, Miaomiao and Katayama, Hiroyuki},
  title = {Effects of surface hydrophobicity on the removal of F-specific RNA phages from reclaimed water by coagulation and ceramic membrane microfiltration},
  journal = {Water Science & Technology},
  year = {2023},
  doi = {10.2166/wst.2023.133}
}
Kostenlos starten →