Fachartikel in der Zeitschrift Water Science and Technology, 2023. Verfasst von Peng Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Urban Stormwater System and Water Environment (Ministry of Education), Beijing University of Civil Engineering and Architecture, Be…. Hauptthemen laut MEDLINE: Water Movements, Rain. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: the National Key R & D Program of the Science and Technology of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Volume capture ratio of annual rainfall (VCRAR) is the key parameter of low-impact development (LID) facilities design, which is significantly affected by the rainfall event division method. However, there is no universal agreement on how to determine an optimal division method to achieve it. A modified minimum inter-event time (MIT) method based on MATLAB software was proposed to find an optimal MIT value. The result showed that the optimal MIT value in Beijing is 200 min based on the daily rainfall data from 1987 to 2016, and the annual average rainfall events were 34.2 with an average rainfall depth of 13.7 mm. Taking bioretention facilities as an example, the errors of design VCRAR under different MIT values were compared based on a Stormwater Management Model (SWMM). The results showed that when design VCRAR was ≤50, 55–60, 60–75, 75–80 and >80%, the optimal MIT value for LID facilities design was 60, 120, 200, 360 and 1,440 min, respectively. Therefore, the optimal MIT should be flexibly selected with the changing of design VCRAR, to ensure that LID facilities meet the design goals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Water MovementsRainHydrologyBeijing

Autor:innen und Institutionen

  • Key Laboratory of Urban Stormwater System and Water Environment (Ministry of Education), Beijing University of Civil Engineering and Architecture, Beijing 100044, China E-mail: wangjianlong@bucea.edu.cn.
  • Key Laboratory of Urban Stormwater System and Water Environment (Ministry of Education), Beijing University of Civil Engineering and Architecture, Beijing 100044, China E-mail: wangjianlong@bucea.edu.cn; Beijing Univers…

Förderung

  • the National Key R & D Program of the Science and Technology of China
  • National Natural Science Foundation of China

Zitieren

APA

Wang, P., Wang, J., Yang, Z., Li, K., Qiu, R., Zhang, C., & Li, J. (2023). Effect of different MIT rainfall event division methods on volume capture ratio of annual rainfall based on bioretention assessment. Water Science and Technology. https://doi.org/10.2166/wst.2023.062

Vancouver

Wang P, Wang J, Yang Z, Li K, Qiu R, Zhang C, et al. Effect of different MIT rainfall event division methods on volume capture ratio of annual rainfall based on bioretention assessment. Water Science and Technology. 2023. doi:10.2166/wst.2023.062

BibTeX
@article{Wang2023,
  author = {Wang, Peng and Wang, Jianlong and Yang, Zitong and Li, Kai and Qiu, Rongting and Zhang, Changhe and Li, Junqi},
  title = {Effect of different MIT rainfall event division methods on volume capture ratio of annual rainfall based on bioretention assessment},
  journal = {Water Science and Technology},
  year = {2023},
  doi = {10.2166/wst.2023.062}
}
Kostenlos starten →