EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Fe and Al based coagulants and disinfectants on polyethylene microplastics removal in coagulation process through response surface methodology

Fatemeh Tabatabaei, Roya Mafigholami, Hamid Moghimi, Sanaz Khoramipoor

Water Science and Technology · 2023

DOI: 10.2166/wst.2022.393 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Science and Technology, 2023. Verfasst von Fatemeh Tabatabaei und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Environmental Science and Engineering, Islamic Azad University, West Tehran Branch, Tehran, Iran E-mail: r.mafigholami@wtiau.ac.ir. Hauptthemen laut MEDLINE: Disinfectants, Water Pollutants, Chemical, Water Purification. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microplastic (MP) pollution has been rising as a threatening risk and recently has appealed to the attention of more researchers. In this study, influential parameters affecting the removal rate of polyethylene microplastics (PEMPs) were optimized through response surface methodology (RSM). In Box Behnken Design (BBD), independent parameters were pH, PEMP size, coagulant dosage and polyacrylamide dosage. Two experimental sets were conducted, one with ferric chloride and the second with poly aluminum chloride as two commonly applied coagulants in drinking water treatment plants (DWTPs). Comparing the results of optimized parameters, PAC was a better coagulant with the predicted removal rate of 58.19%, while the removal rate with ferric chloride as a coagulant was predicted to be 56.37%. Moreover, some experiments were conducted to analyze the effect of ozone gas and sodium hypochlorite as disinfectants on removal rate. The highest removal rate was observed when 2 ppm of O3 was added to the solution coagulated with optimal dosage of PAC, reaching the removal rate of 76.8%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DisinfectantsWater Pollutants, ChemicalWater PurificationMicroplasticsPlasticsPolyethyleneFlocculationChloridesFerric Compounds

Substanzen

MicroplasticsPlasticsPolyethyleneDisinfectantsWater Pollutants, Chemicalferric chlorideChloridesFerric Compounds

Autor:innen und Institutionen

  • Faculty of Environmental Science and Engineering, Islamic Azad University, West Tehran Branch, Tehran, Iran E-mail: r.mafigholami@wtiau.ac.ir.
  • Department of Microbiology, University of Tehran, Tehran, Iran.

Zitieren

APA

Tabatabaei, F., Mafigholami, R., Moghimi, H., & Khoramipoor, S. (2023). Effect of Fe and Al based coagulants and disinfectants on polyethylene microplastics removal in coagulation process through response surface methodology. Water Science and Technology. https://doi.org/10.2166/wst.2022.393

Vancouver

Tabatabaei F, Mafigholami R, Moghimi H, Khoramipoor S. Effect of Fe and Al based coagulants and disinfectants on polyethylene microplastics removal in coagulation process through response surface methodology. Water Science and Technology. 2023. doi:10.2166/wst.2022.393

BibTeX
@article{Tabatabaei2023,
  author = {Tabatabaei, Fatemeh and Mafigholami, Roya and Moghimi, Hamid and Khoramipoor, Sanaz},
  title = {Effect of Fe and Al based coagulants and disinfectants on polyethylene microplastics removal in coagulation process through response surface methodology},
  journal = {Water Science and Technology},
  year = {2023},
  doi = {10.2166/wst.2022.393}
}
Kostenlos starten →