EUVIMEDEUVIMED entdecken
Studienprotokoll

IRR-M: a sensor-redundant solar smart-irrigation prototype and validation protocol

Mohamed E. Yousef, Amal M. Abdel-Hameed, Mohamed M. Mahmoud

Water Practice & Technology · 01.10.2026 · 21 (10) · 5778-5792

DOI: 10.2166/wpt.2026.468 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Water Practice & Technology, online erschienen am 24.09.2026. Verfasst von Mohamed E. Yousef und 2 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Solar irrigation can reduce dependence on diesel and unreliable grid electricity, but solar pumping alone does not guarantee efficient water use. The IRR-M (IRRigation Monitoring and Management) prototype, a solar-powered smart-irrigation unit in which the sensing layer is deliberately redundant: two or more independent measurement channels are provided for each control-critical variable so that no single sensor failure, drift or stuck value can by itself start or stop an irrigation event. Redundancy here denotes fault tolerance and back-up provision, not unnecessary instrumentation. Four items of engineering evidence are reported in place of unsupported field-performance claims. First, a component-level specification defines transducer ratings, measurement ranges and the triangular arrangement of the redundant soil-moisture probes. Second, a closed daily energy balance for a 0.5 ha drip unit gives 36.1 m3 d−1 of applied water, 2.46 kWh d−1 of hydraulic energy and 5.61 kWh d−1 of total electrical demand, met by a 1.5 kWp array and a 60 Ah, 48 V battery. Third, a reproducible 2 × 106-realisation Monte-Carlo verification of median-of-three voting gives a normalized RMSE of 0.670σ for independent channel errors, equivalent to a 33.0% reduction relative to a single channel; the reduction falls to 14.9% at an inter-channel error correlation of 0.5 and 5.7% at 0.8. Exact 2-out-of-3 reliability analysis increases control-loop availability from 95.0% to 99.3% when per-channel availability is set to 0.95. Fourth, irrigation trigger and cut-off thresholds are derived for a sandy loam (θ_ON = 0.172 m3 m−3, θ_OFF = 0.210 m3 m−3) together with the sensor accuracy required to resolve that band. The bench-scale experiment remains pre-registered and unexecuted; the accompanying numerical code reproduces only calculations that do not require unobserved pilot parameters, while full-season and machine-learning analyses remain conditional on measured calibration and fault data. Numerical indicators carried over from earlier development documentation are retained only as stated hypotheses.

Zitieren

APA

Yousef, M. E., Abdel-Hameed, A. M., & Mahmoud, M. M. (2026). IRR-M: a sensor-redundant solar smart-irrigation prototype and validation protocol. Water Practice & Technology, 21(10), 5778-5792. https://doi.org/10.2166/wpt.2026.468

Vancouver

Yousef ME, Abdel-Hameed AM, Mahmoud MM. IRR-M: a sensor-redundant solar smart-irrigation prototype and validation protocol. Water Practice & Technology. 2026;21(10):5778-5792. doi:10.2166/wpt.2026.468

BibTeX
@article{Yousef2026,
  author = {Yousef, Mohamed E. and Abdel-Hameed, Amal M. and Mahmoud, Mohamed M.},
  title = {IRR-M: a sensor-redundant solar smart-irrigation prototype and validation protocol},
  journal = {Water Practice & Technology},
  year = {2026},
  volume = {21},
  number = {10},
  pages = {5778--5792},
  doi = {10.2166/wpt.2026.468}
}
Kostenlos starten →