EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing long-term specific pollutant loads in municipal wastewater plants influent using monitoring data: A case study from Latvia

Juris Laicans iD, Brigita Dejus iD, Sandis Dejus iD, Talis Juhna iD

Journal of Water and Health · 01.06.2026 · 24 (6) · 830-843

DOI: 10.2166/wh.2026.240 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Water and Health, online erschienen am 18.06.2026. Verfasst von Juris Laicans und 3 weiteren Autor:innen. Beteiligte Einrichtung: Water Systems and Biotechnology Institute, Riga Technical University, Kipsalas iela 6A-263, Riga, Latvia E-mail: juris.laicans@rtu.lv. Hauptthemen laut MEDLINE: Wastewater, Environmental Monitoring, Water Pollutants, Chemical, Waste Disposal, Fluid. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The work was supported by the EU Recovery and Resilience Facility within Project No 5.2.1.1.i.0/2/24/I/CFLA/003 "Implementation of consolidation and management….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diagram showing how population, weather and urban activities influence wastewater composition, where parameters BOD5, COD, N, NH4-N, P and PO4-P are analysed to support wastewater-based epidemiology normalization. Wastewater-based epidemiology uses data from wastewater treatment plants to monitor the health of a population, but requires accurate normalization to provide per-capita, or individual-based, health indicators. This study assessed the long-term stability and suitability of key wastewater parameters for population normalization using data from 45 treatment plants across Latvia over a ten-year period, representing two-thirds of the national population. Specific pollutant loads were calculated for biochemical oxygen demand, chemical oxygen demand, total nitrogen, ammonium nitrogen, total phosphorus, and orthophosphate. Overall, pollutant loads remained stable during the study period, though an increase was observed in recent years, with ammonium rising by 27%, total nitrogen by 15%, and phosphorus by 11%. Industrial plants consistently showed higher pollutant loads than municipal facilities. Nitrogen exhibited the lowest variability among the evaluated hydrochemical parameters, suggesting its suitability as a robust normalization indicator within the studied dataset, while chemical oxygen demand can serve as a supporting indicator. In contrast, biochemical oxygen demand and phosphorus were less suitable due to operational sensitivity and high variability. The study recommends using rolling, plant-specific median values over two to three years to enhance the precision and comparability of population-normalized wastewater-based health assessments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterEnvironmental MonitoringWater Pollutants, ChemicalWaste Disposal, FluidLatviaPhosphorusNitrogenBiological Oxygen Demand Analysis

Stichwörter der Autor:innen

WBEmonitoringpollutant loadspopulation biomarkers

Substanzen

WastewaterPhosphorusWater Pollutants, ChemicalNitrogen

Autor:innen und Institutionen

  • Water Systems and Biotechnology Institute, Riga Technical University, Kipsalas iela 6A-263, Riga, Latvia E-mail: juris.laicans@rtu.lv.
  • Water Systems and Biotechnology Institute, Riga Technical University, Kipsalas iela 6A-263, Riga, Latvia.

ORCID-Profile: Juris Laicans, Brigita Dejus, Sandis Dejus, Talis Juhna

Förderung

  • The work was supported by the EU Recovery and Resilience Facility within Project No 5.2.1.1.i.0/2/24/I/CFLA/003 "Implementation of consolidation and management…

Zitieren

APA

Laicans, J., Dejus, B., Dejus, S., & Juhna, T. (2026). Assessing long-term specific pollutant loads in municipal wastewater plants influent using monitoring data: A case study from Latvia. Journal of Water and Health, 24(6), 830-843. https://doi.org/10.2166/wh.2026.240

Vancouver

Laicans J, Dejus B, Dejus S, Juhna T. Assessing long-term specific pollutant loads in municipal wastewater plants influent using monitoring data: A case study from Latvia. Journal of Water and Health. 2026;24(6):830-843. doi:10.2166/wh.2026.240

BibTeX
@article{Laicans2026,
  author = {Laicans, Juris and Dejus, Brigita and Dejus, Sandis and Juhna, Talis},
  title = {Assessing long-term specific pollutant loads in municipal wastewater plants influent using monitoring data: A case study from Latvia},
  journal = {Journal of Water and Health},
  year = {2026},
  volume = {24},
  number = {6},
  pages = {830--843},
  doi = {10.2166/wh.2026.240}
}
Kostenlos starten →