Comparative evaluation of heating instruments for detecting Bacteroides HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP
Journal of Water and Health · 01.06.2025 · 23 (6) · 701-714
DOI: 10.2166/wh.2025.327 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Water and Health, online erschienen am 05.05.2025. Verfasst von Mariah C A do Nascimento und 7 weiteren Autor:innen. Beteiligte Einrichtung: CSIRO Environment, Ecosciences Precinct, 41 Boggo Road, Brisbane, QLD 4102, Australia. Hauptthemen laut MEDLINE: Wastewater, SARS-CoV-2, Nucleic Acid Amplification Techniques, Colorimetry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study assessed the accuracy, field suitability, and cost-effectiveness of colorimetric LAMP (c-LAMP) assays using six heating instruments: Electric Kettle, Water Bath, Heating Block, miniPCR, Thermocycler, and Genie® III. Bacteroides HF183 (HF183), SARS-CoV-2, and Aichi virus A (AiV-A) were tested using control materials and wastewater samples, comparing cLAMP with qPCR/RT-qPCR detection. qPCR/RT-qPCR reliably detected HF183 and AiV-A genetic fragments at dilutions as low as 1 × 10−5 pg/μL, corresponding to 1.24 and 1.49 log10 GC/reaction. cLAMP/RT-cLAMP detected these fragments at 1 × 10−4 pg/μL (2.28 and 2.63 log10 GC/reaction), though Electric Kettle, miniPCR, and Genie® III occasionally produced false negatives. RT-qPCR reliably detected SARS-CoV-2 fragments at 1 × 100 GC/μL (1.86 log10 GC/reaction), with cLAMP/RT-cLAMP performing similarly across most instruments except Thermocycler. No significant differences (p > 0.05) were observed among instruments, though inconsistencies appeared at lower concentrations. The findings offer valuable insights into heating instrument performance for cLAMP/RT-cLAMP assays, guiding their application in wastewater-based pathogen detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CSIRO Environment, Ecosciences Precinct, 41 Boggo Road, Brisbane, QLD 4102, Australia.
- Department of Biology, São Paulo State University - UNESP, São José do Rio Preto, São Paulo 15054-000, Brazil.
- State Key Laboratory of Marine Environmental Science, College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
- Department of Civil & Environmental Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
- CSIRO Environment, Ecosciences Precinct, 41 Boggo Road, Brisbane, QLD 4102, Australia E-mail: warish.ahmed@csiro.au.
Zitieren
APA
do Nascimento, M. C. A., Smith, W. J. M., Liu, Y., da Costa, V. G., Simpson, S. L., Bivins, A., Rahal, P., & Ahmed, W. (2025). Comparative evaluation of heating instruments for detecting Bacteroides HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP. Journal of Water and Health, 23(6), 701-714. https://doi.org/10.2166/wh.2025.327
Vancouver
do Nascimento MCA, Smith WJM, Liu Y, da Costa VG, Simpson SL, Bivins A, et al. Comparative evaluation of heating instruments for detecting Bacteroides HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP. Journal of Water and Health. 2025;23(6):701-714. doi:10.2166/wh.2025.327
BibTeX
@article{doNascimento2025,
author = {do Nascimento, Mariah C A and Smith, Wendy J M and Liu, Yawen and da Costa, Vivaldo Gomes and Simpson, Stuart L and Bivins, Aaron and Rahal, Paula and Ahmed, Warish},
title = {Comparative evaluation of heating instruments for detecting Bacteroides HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP},
journal = {Journal of Water and Health},
year = {2025},
volume = {23},
number = {6},
pages = {701--714},
doi = {10.2166/wh.2025.327}
}
EUVIMED