ENHANCEMENT OF TENSION LAP SPLICE IN HPC USING DIFFERENT TECHNIQUES
International Journal of Advances in Structural and Geotechnical Engineering · 2019
DOI: 10.21608/asge.2019.270765 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Advances in Structural and Geotechnical Engineering, 2019.
Abstract (Originalsprache)
High Performance Concrete (HPC) with favorable material properties has been commonly used in different reinforced concrete projects such as bridges, tunnels, tall buildings and parking garages. Due to the limited lengths of manufactured reinforcement steel bars, splicing of these bars is urgently required for long span structures. Since lap splice is considered as the most economic and the easiest way for linking reinforcement steel bars, an experimental study on 21 lap splices embedded in HPC specimens was performed under direct tension test. Five different techniques were employed for straight and anchored bars with several splice lengths in order to obtain the minimum lap splice length for transferring the design force of the bars. For straight bars, spiral confinement with either inner or outer linking bars was used. On the other hand, for anchored bars, hooks, hooks with cross bars and end bearing plates were used. It was found that a splice length of 10 d b was sufficient to achieve nominal yield stress of reinforcement in case of using spiral confinement with inner linking bars. On contrary, 5 d b length of splice was found enough for all anchored bars to achieve their design force. Developing an innovative technique of end bearing plate for G2-P leaded to the same mode of failure for all subgroup specimens. The specimens of G2-P showed rapture of reinforcing bars with maximum potential strength of steel. During testing of G2-P specimens, the movable plates converted the tension force of bars into compression force acting on concrete in front of the plate. This action played a role of reducing the direct tension cracks of concrete during testing especially in short lap splice specimens G2-P-5d and G2-P-10d which remained without cracking until failure. Fig. shows the compression force created on the face of bearing plates.
Zitieren
APA
(2019). ENHANCEMENT OF TENSION LAP SPLICE IN HPC USING DIFFERENT TECHNIQUES. International Journal of Advances in Structural and Geotechnical Engineering. https://doi.org/10.21608/asge.2019.270765
Vancouver
ENHANCEMENT OF TENSION LAP SPLICE IN HPC USING DIFFERENT TECHNIQUES. International Journal of Advances in Structural and Geotechnical Engineering. 2019. doi:10.21608/asge.2019.270765
BibTeX
@article{euvimed2019,
title = {ENHANCEMENT OF TENSION LAP SPLICE IN HPC USING DIFFERENT TECHNIQUES},
journal = {International Journal of Advances in Structural and Geotechnical Engineering},
year = {2019},
doi = {10.21608/asge.2019.270765}
}