Metrological calibration and uncertainty evaluation of MEMS accelerometers for structural health monitoring in seismic regions

Akmaljon Mamatov, Xusniddin Sotvoldiyev, Miraziz Talipov, Said Shaumarov, Konul Gafarbayli, Diyorbek Bekmirzaev

Vibroengineering Procedia · 08.06.2026 · 62 · 140-144

DOI: 10.21595/vp.2026.26360 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vibroengineering Procedia, online erschienen am 08.06.2026. Verfasst von Akmaljon Mamatov und 5 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a metrological assurance framework for MEMS accelerometers used in structural health monitoring (SHM) of buildings in seismically active regions. The methodology integrates ISO 16063-21 calibration, JCGM 100 (GUM) uncertainty evaluation, and field validation. Three MEMS accelerometers (ADXL355, MPU-6050, LIS3DHH) were calibrated across 1-200 Hz at 0.1-1.0 g. The expanded uncertainty ( k = 2) ranged from 2.3 % to 5.8 %. Field validation on a five-story building in Tashkent confirmed that the ADXL355 estimates natural frequencies within 1.2 % of a reference accelerometer ( R 2 = 0.999). The ADXL355 satisfies ISO 16063-21 requirements and provides adequate performance for seismic zones VII-IX. The proposed framework contributes to standardized low-cost vibration monitoring procedures in Central Asia.

Zitieren

APA

Mamatov, A., Sotvoldiyev, X., Talipov, M., Shaumarov, S., Gafarbayli, K., & Bekmirzaev, D. (2026). Metrological calibration and uncertainty evaluation of MEMS accelerometers for structural health monitoring in seismic regions. Vibroengineering Procedia, 62, 140-144. https://doi.org/10.21595/vp.2026.26360

Vancouver

Mamatov A, Sotvoldiyev X, Talipov M, Shaumarov S, Gafarbayli K, Bekmirzaev D. Metrological calibration and uncertainty evaluation of MEMS accelerometers for structural health monitoring in seismic regions. Vibroengineering Procedia. 2026;62:140-144. doi:10.21595/vp.2026.26360

BibTeX
@article{Mamatov2026,
  author = {Mamatov, Akmaljon and Sotvoldiyev, Xusniddin and Talipov, Miraziz and Shaumarov, Said and Gafarbayli, Konul and Bekmirzaev, Diyorbek},
  title = {Metrological calibration and uncertainty evaluation of MEMS accelerometers for structural health monitoring in seismic regions},
  journal = {Vibroengineering Procedia},
  year = {2026},
  volume = {62},
  pages = {140--144},
  doi = {10.21595/vp.2026.26360}
}
Kostenlos starten →