EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Creation of Three New Optotypes Chart and Evaluation of the Reliability on Healthy Subjects

Ungsoo Samuel Kim iD

Clinical Ophthalmology · 2026-03 · Volume 20 · 1-5

DOI: 10.2147/opth.s572209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Ophthalmology, 2026-03. Verfasst von Ungsoo Samuel Kim. Beteiligte Einrichtung: Department of Ophthalmology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong-si, Korea. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To design a new optotype that is not based on any Roman character.

Methods

Fifty healthy adults (12 men and 38 women), aged between 20-35 years, were enrolled. Three new optototypes were designed. The first is an open square, the second is a horned square, and the last is a horned circle. The main outcome is the correlation between Landolt C visual acuity and that measured using the 3 newly designed optotypes.

Results

Mean subject age was 27.2 ± 3.7 years. Corrected visual acuity scores were similar across all five tests. Under fogging, the three new optotypes yielded significantly lower scores than Tumbling E and no significant difference was found between the Landolt C and the new optotypes. Bland-Altman analysis showed minimal bias and the closest agreement with Landolt C for the open square optotype, especially under fogging conditions (Bias: -0.006; 95% LoA: -0.172 to 0.160). All five tests were significantly correlated (P < 0.001), with the open square showing the strongest correlation with Landolt C. Among subjects, 33% had ≥1 diopter of with-the-rule astigmatism, but fogging did not reveal differences between astigmats and non-astigmats. Visual acuity was higher in non-astigmats for all optotypes except the open square.

Conclusion

Three newly developed and conventional optotypes including the Landolt C and Tumbling E tests to be similarly effective in measuring visual acuity. These optotypes can be considered as combinations of the Landolt C test.

Schlagwörter

Stichwörter der Autor:innen

optotypesvision testvisual acuity test

Autor:innen und Institutionen

  • Department of Ophthalmology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong-si, Korea.
  • Department of Ophthalmology, Chung-Ang University College of Medicine, Seoul, Korea.

ORCID-Profile: Ungsoo Samuel Kim

Zitieren

APA

Kim, U. S. (2026). Creation of Three New Optotypes Chart and Evaluation of the Reliability on Healthy Subjects. Clinical Ophthalmology, Volume 20, 1-5. https://doi.org/10.2147/opth.s572209

Vancouver

Kim US. Creation of Three New Optotypes Chart and Evaluation of the Reliability on Healthy Subjects. Clinical Ophthalmology. 2026;Volume 20:1-5. doi:10.2147/opth.s572209

BibTeX
@article{Kim2026,
  author = {Kim, Ungsoo Samuel},
  title = {Creation of Three New Optotypes Chart and Evaluation of the Reliability on Healthy Subjects},
  journal = {Clinical Ophthalmology},
  year = {2026},
  volume = {Volume 20},
  pages = {1--5},
  doi = {10.2147/opth.s572209}
}
Kostenlos starten →