EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Factors Affecting Ray Trace LASIK Data Acquisition in Clinical Practice: Options for Addressing Accommodation

Akshaya L Thananjeyan, Chandra Bala iD

Clinical Ophthalmology · 2025-07 · Volume 19 · 2079-2089

DOI: 10.2147/opth.s524774 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Ophthalmology, 2025-07. Verfasst von Akshaya L Thananjeyan und 1 weiteren Autor:innen. Beteiligte Einrichtung: PersonalEyes, Sydney, NSW, Australia. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess factors affecting successful data acquisition for InnovEyes guided ray trace LASIK.

Setting

Single-site ophthalmology practice.

Design

Retrospective review.

Methods

A total of 1283 eyes with myopia and myopic astigmatism were assessed over 18-months for ray trace-based LASIK planning. Preoperative measurements were acquired using the InnovEyes Sightmap (Wavelight Plus, Alcon). Scan time per eye, number of scans, pupil size, calculated refraction and manifest spherical equivalent (SEQ) refraction were assessed. In a subset of eyes with significant accommodation, aberrometry-based refraction was adjusted prior to treatment, or cycloplegic measurement was used for treatment planning. In these subsets, 3-month post-operative refractive outcomes were analysed.

Results

Mean noncycloplegic scanning time (11.10±14.11 minutes/eye to 8.10±3.17 minutes/eye) and number of noncycloplegic scans per eye (6.28±2.97 scans to 5.23±2.12 scans) decreased over time. In nine eyes where the wavefront SEQ (4 mm) was less myopic (by 0.5D or more) than the manifest SEQ and no adjustment was made, all achieved uncorrected distance visual acuity (UDVA) of 20/20 or better. In 274 eyes (21.4%), wavefront SEQ (4mm) was more myopic (by > 0.5D) than manifest SEQ. Surgeon adjusted treatment in 95 eyes to within 0.5D of manifest SEQ resulted in 98% achieving UDVA of 20/20 or greater. In 23 eyes treated using cycloplegic wavefront data, 96% achieved UDVA of 20/20 or greater.

Conclusion

Use of the InnovEyes Sightmap system for ray trace LASIK is feasible in a clinical environment but demonstrates an operator learning curve. Accommodation during wavefront measurement can occur; this can be managed through surgeon adjustment of treatment or the use of cycloplegic wavefront data.

Schlagwörter

Stichwörter der Autor:innen

accommodationhigher order aberrationlaser in situ keratomileusisray trace

Autor:innen und Institutionen

  • PersonalEyes, Sydney, NSW, Australia.
  • Emergency Department, Sydney Hand and Eye Hospital, Sydney, NSW, Australia.

ORCID-Profile: Chandra Bala

Zitieren

APA

Thananjeyan, A. L., & Bala, C. (2025). Factors Affecting Ray Trace LASIK Data Acquisition in Clinical Practice: Options for Addressing Accommodation. Clinical Ophthalmology, Volume 19, 2079-2089. https://doi.org/10.2147/opth.s524774

Vancouver

Thananjeyan AL, Bala C. Factors Affecting Ray Trace LASIK Data Acquisition in Clinical Practice: Options for Addressing Accommodation. Clinical Ophthalmology. 2025;Volume 19:2079-2089. doi:10.2147/opth.s524774

BibTeX
@article{Thananjeyan2025,
  author = {Thananjeyan, Akshaya L and Bala, Chandra},
  title = {Factors Affecting Ray Trace LASIK Data Acquisition in Clinical Practice: Options for Addressing Accommodation},
  journal = {Clinical Ophthalmology},
  year = {2025},
  volume = {Volume 19},
  pages = {2079--2089},
  doi = {10.2147/opth.s524774}
}
Kostenlos starten →