EUVIMEDEUVIMED entdecken
FallberichtKlinische StudieOpen Access · CC BY-NC 3.0

International Multicenter, Myopic and Myopic Astigmatism Femto LASIK, Customized by Automated Ray-Tracing Ablation Profile Calculation: A Postmarket Study

Anastasios John Kanellopoulos iD, Matthias Maus, Chandra Bala iD, Cody Hamilton, Sissimos Lemonis, Maria Elena Jockovich, Ramin Khoramnia iD

Clinical Ophthalmology · 2024-02 · Volume 18 · 525-536

DOI: 10.2147/opth.s435581 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Clinical Ophthalmology, 2024-02. Verfasst von Anastasios John Kanellopoulos und 6 weiteren Autor:innen. Beteiligte Einrichtung: LaserVision Ambulatory Surgical Unit, Athens, Greece. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the safety and efficacy of a customized ablation treatment (InnovEyes) to correct myopia and myopic astigmatism with femtosecond laser-assisted in situ keratomileusis (Femto LASIK). Patients and Methods: In this prospective, nonrandomized, multicenter study, 113 patients (225 eyes) with preoperative myopia less than -9.0 diopters (D) and astigmatism 0 to -4.0 D (based on InnovEyes refraction) underwent wavefront, tomography, and biometry assessment using a single diagnostic device (InnovEyes sightmap). These data were imported and used unmodified by the InnovEyes algorithm to automatically calculate and optimize correction of lower- and higher‑order aberrations (HOAs) treated by the EX500 ablation profile. Visual acuity, refractive error, HOAs, and patient satisfaction were evaluated over 3 months.

Results

A total of 106 patients (212 eyes) completed the study and were included in the analysis. Mean preoperative manifest refraction spherical equivalent (MRSE) was -3.38±1.76 D. At Month 3, uncorrected distance visual acuity was 20/20 or better in 208/212 (98.1%) eyes, and it was the same as, or better than, the preoperative best-corrected distance visual acuity (CDVA) in 162/212 (76.4%) eyes; 76/212 (35.8%) eyes gained ≥1 line of CDVA. MRSE was within ±0.5 D in 195/212 (92.0%) eyes. Additionally, 201/209 (96.2%) eyes had no change (defined as a change between -0.1 μm and 0.1 μm, inclusive) in HOAs, and 105/106 (99.1%) patients reported to be satisfied with the results.

Conclusion

Customizing ray-tracing Femto LASIK with this platform appeared safe and effective in correcting myopic astigmatism and also achieved a significant percentage of eyes gaining lines of vision, potentially by addressing HOAs, along with a consistently high level of patient satisfaction.

Schlagwörter

Stichwörter der Autor:innen

corrected distance visual acuityhigher-order aberrationsmanifest refraction spherical equivalentmyopic astigmatism

Autor:innen und Institutionen

  • LaserVision Ambulatory Surgical Unit, Athens, Greece.
  • Department of Ophthalmology, NYU Grossman School of Medicine, New York City, NY, USA.
  • Sehkraft Augenzentrum, Köln, Germany.
  • PersonalEyes, Sydney, NSW, Australia.
  • Alcon Vision, LLC, Fort Worth, TX, USA.
  • Alcon Deutschland GmbH, Freiburg, Germany.

ORCID-Profile: Anastasios John Kanellopoulos, Chandra Bala, Ramin Khoramnia

Zitieren

APA

Kanellopoulos, A. J., Maus, M., Bala, C., Hamilton, C., Lemonis, S., Jockovich, M. E., & Khoramnia, R. (2024). International Multicenter, Myopic and Myopic Astigmatism Femto LASIK, Customized by Automated Ray-Tracing Ablation Profile Calculation: A Postmarket Study. Clinical Ophthalmology, Volume 18, 525-536. https://doi.org/10.2147/opth.s435581

Vancouver

Kanellopoulos AJ, Maus M, Bala C, Hamilton C, Lemonis S, Jockovich ME, et al. International Multicenter, Myopic and Myopic Astigmatism Femto LASIK, Customized by Automated Ray-Tracing Ablation Profile Calculation: A Postmarket Study. Clinical Ophthalmology. 2024;Volume 18:525-536. doi:10.2147/opth.s435581

BibTeX
@article{Kanellopoulos2024,
  author = {Kanellopoulos, Anastasios John and Maus, Matthias and Bala, Chandra and Hamilton, Cody and Lemonis, Sissimos and Jockovich, Maria Elena and Khoramnia, Ramin},
  title = {International Multicenter, Myopic and Myopic Astigmatism Femto LASIK, Customized by Automated Ray-Tracing Ablation Profile Calculation: A Postmarket Study},
  journal = {Clinical Ophthalmology},
  year = {2024},
  volume = {Volume 18},
  pages = {525--536},
  doi = {10.2147/opth.s435581}
}
Kostenlos starten →