Comparing the Performance of Two Cryptococcal Antigen Detection Tests: Chemiluminescence vs Colloidal Gold Methods
Infection and Drug Resistance · 2024-12 · Volume 17 · 5639-5647
DOI: 10.2147/idr.s491846 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection and Drug Resistance, 2024-12. Verfasst von Xiao-Yun Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre of Laboratory Medicine, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, People's Rep…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Objective
To compare the performance of a new chemiluminescence method with that of the traditional colloidal gold method for cryptococcal antigen (CrAg) detection.
Methods
Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as the gold standard for early diagnosis. In this study, a total of 140 samples (92 serum and 48 cerebrospinal fluid samples) from 140 patients with suspected cryptococcosis collected between January 2022 and September 2023 at Zhejiang Provincial People's Hospital were tested via a fully automated chemiluminescent immunoassay analyser (SuperFlex) from Suzhou Xinbo and a cryptococcal antigen detection kit (colloidal gold method) from the IMMY Company of the United States.
Results
According to the diagnostic criteria for cryptococcosis, 55 of the 140 suspected patients were diagnosed with cryptococcosis (39.3%), including 47 with pulmonary cryptococcosis (PC) and 8 with cryptococcal meningitis (CM). The degree of agreement between chemiluminescence and the colloidal gold method was analysed via Cohen's kappa coefficient, which was 0.970 (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre of Laboratory Medicine, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, People's Republic of China.
Zitieren
APA
Yu, X. Y., Zhang, L., Hu, Y., Zhu, Z., Zhu, Y., & Li, X. (2024). Comparing the Performance of Two Cryptococcal Antigen Detection Tests: Chemiluminescence vs Colloidal Gold Methods. Infection and Drug Resistance, Volume 17, 5639-5647. https://doi.org/10.2147/idr.s491846
Vancouver
Yu XY, Zhang L, Hu Y, Zhu Z, Zhu Y, Li X. Comparing the Performance of Two Cryptococcal Antigen Detection Tests: Chemiluminescence vs Colloidal Gold Methods. Infection and Drug Resistance. 2024;Volume 17:5639-5647. doi:10.2147/idr.s491846
BibTeX
@article{Yu2024,
author = {Yu, Xiao-Yun and Zhang, Lei and Hu, Yueyue and Zhu, Zhongliang and Zhu, Yongze and Li, Xi},
title = {Comparing the Performance of Two Cryptococcal Antigen Detection Tests: Chemiluminescence vs Colloidal Gold Methods},
journal = {Infection and Drug Resistance},
year = {2024},
volume = {Volume 17},
pages = {5639--5647},
doi = {10.2147/idr.s491846}
}
EUVIMED