EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Performance of Two Matrix-Assisted Laser Desorption Ionization–Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of the Viridans Group Streptococci

Fen Pan, Na Zhao, Wantong Zhao, Chun Wang iD, Yan Sun, Haomin Zhang, Juanxiu Qin, Qian Liu, Hong Zhang

Infection and Drug Resistance · 2023-05 · Volume 16 · 2901-2909

DOI: 10.2147/idr.s407667 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infection and Drug Resistance, 2023-05. Verfasst von Fen Pan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of Ch…. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Due to similar colony morphology among viridans group streptococci (VGS), the differentiation of VGS species remains difficult in routine clinical microbiology. Recently, matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) has been described as a fast method for identifying various bacteria at species level, and also for the VGS strains.

Methods

A total of 277 VGS isolates were identified with the two MALDI-TOF MS systems (VITEK MS and Bruker Biotyper). The tuf and rpoB gene sequencing was used as the reference identification method for comparison.

Results

Based on tuf and rpoB gene sequencing, 84 isolates were S. pneumoniae and 193 strains were other VGS isolates including S. anginosus group (n=91, 47.2%), S. mitis group (n=80, 41.5%), S. bovis group (n=11, 5.7%), S. salivarius group (n=10, 5.2%), and S. mutans group (n=1, 0.5%). VITEK MS and Bruker Biotyper accurately identified 94.6% and 89.9% of all VGS isolates, respectively. VITEK MS showed better identification results than Bruker Biotyper for S. mitis group including S. pneumoniae and S. bovis group, but for other VGS isolates, two MALDI-TOF MS systems showed comparable identification performance. However, VITEK MS was able to identify S. gallolyticus to the subspecies level with high-confidence (S. gallolyticus ssp. pasteurianus), while the Bruker Biotyper system could not. While Bruker Biotyper system could be able to correctly differentiate the subspecies of S. salivarius from S. vestibularis, VITEK MS poorly identify.

Conclusion

This study demonstrated that two MALDI-TOF MS systems allowed discrimination for most VGS isolates with different identification performance, but Bruker Biotyper could produce more misidentifications and VITEK MS system. It is crucial to be familiar with the performance of MALDI-TOF MS systems used in clinical microbiology.

Schlagwörter

Stichwörter der Autor:innen

MALDI-TOF MSStreptococcus pneumoniaeidentificationviridans group streptococci

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
  • Institute of Pediatric Infection, Immunity, and Critical Care Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, 200062, People's Republic of China.
  • Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People's Republic of China.

ORCID-Profile: Chun Wang

Zitieren

APA

Pan, F., Zhao, N., Zhao, W., Wang, C., Sun, Y., Zhang, H., Qin, J., Liu, Q., & Zhang, H. (2023). Performance of Two Matrix-Assisted Laser Desorption Ionization–Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of the Viridans Group Streptococci. Infection and Drug Resistance, Volume 16, 2901-2909. https://doi.org/10.2147/idr.s407667

Vancouver

Pan F, Zhao N, Zhao W, Wang C, Sun Y, Zhang H, et al. Performance of Two Matrix-Assisted Laser Desorption Ionization–Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of the Viridans Group Streptococci. Infection and Drug Resistance. 2023;Volume 16:2901-2909. doi:10.2147/idr.s407667

BibTeX
@article{Pan2023,
  author = {Pan, Fen and Zhao, Na and Zhao, Wantong and Wang, Chun and Sun, Yan and Zhang, Haomin and Qin, Juanxiu and Liu, Qian and Zhang, Hong},
  title = {Performance of Two Matrix-Assisted Laser Desorption Ionization–Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of the Viridans Group Streptococci},
  journal = {Infection and Drug Resistance},
  year = {2023},
  volume = {Volume 16},
  pages = {2901--2909},
  doi = {10.2147/idr.s407667}
}
Kostenlos starten →