EUVIMEDEUVIMED entdecken
VergleichsstudieRandomisierte kontrollierte StudieOpen Access · CC BY-NC 3.0

Labor Analgesia Initiation with Dural Puncture Epidural versus Standard Epidural Techniques: A Prospective Randomized Dose Allocation Study of Ropivacaine

Fei Xiao iD, Dan M Drzymalski, Yu-Fang Dong, Jia-Yue Huang, Yan Gao, Hai-Ya Yan iD, Hui-Jing Hu

Drug Design, Development and Therapy · 2025

DOI: 10.2147/dddt.s547879 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Drug Design, Development and Therapy, 2025. Verfasst von Fei Xiao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, The Affiliated Women and Children's Hospital of Ningbo University, Ningbo, People's Republic of China. Hauptthemen laut MEDLINE: Amides, Analgesia, Epidural, Analgesia, Obstetrical, Anesthetics, Local. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

When compared to the standard epidural technique, the dural puncture epidural (DPE) technique is reported to provide quicker onset of labor analgesia and improved quality of analgesia. Recently, the DPE technique was found to lower the effective dose for 90% (ED90) of patients receiving bupivacaine for labor analgesia by 35%. However, key pharmacological differences between bupivacaine and ropivacaine and the effect of a DPE technique on ropivacaine doses have not been studied. Therefore, we aimed to determine the effective dose for 50% (ED50) and ED90 of ropivacaine for labor analgesia in parturients when initiated with the DPE and standard epidural techniques.

Methods

Study participants were randomized to receive one of the five doses of ropivacaine (12, 15, 18, 21, and 24 mg) undergoing one of the two epidural techniques (either a DPE or standard epidural technique). A total volume of 20 mL of local anesthetic was administered epidurally. Effective analgesia was defined as the patient reporting an NRS pain score < 3 at 20 minutes following drug administration. The ED50 and ED90 values of epidural ropivacaine for labor analgesia were determined using probit analysis, and comparisons were made using the relative median potency ratio.

Results

The ED50 of ropivacaine for initiating labor analgesia using the DPE vs standard epidural techniques was 18.6 mg (95% CI, 16.4 to 21.1 mg) vs 19.2 mg (95% CI, 17.0 to 21.8 mg), respectively. The ED90 values were 30.5 mg (95% CI, 26.6 to 38.3 mg) vs 31.1 mg (95% CI, 27.1 to 39.2 mg), respectively. The relative median potency ratio for ropivacaine with DPE vs standard epidural technique was -0.6 (95% CI, -4.0 to 2.6).

Conclusion

Our findings suggest that there is no dose-sparing effect of ropivacaine when using the DPE technique vs a standard epidural technique for labor analgesia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmidesAnalgesia, EpiduralAnalgesia, ObstetricalAnesthetics, LocalRopivacaineAdultFemaleHumansPregnancyYoung AdultDose-Response Relationship, DrugProspective Studies

Stichwörter der Autor:innen

dose–responsedural puncture epidurallabor analgesiaropivacainestandard epidural

Substanzen

AmidesAnesthetics, LocalRopivacaine

Autor:innen und Institutionen

  • Department of Anesthesiology, The Affiliated Women and Children's Hospital of Ningbo University, Ningbo, People's Republic of China.
  • Department of Anesthesiology, Jiaxing University Affiliated Women and Children Hospital, Jiaxing, People's Republic of China.
  • Tufts Medical Center, Department of Anesthesiology and Perioperative Medicine, Boston, MA, USA.

ORCID-Profile: Fei Xiao, Hai-Ya Yan

Zitieren

APA

Xiao, F., Drzymalski, D. M., Dong, Y. F., Huang, J. Y., Gao, Y., Yan, H. Y., & Hu, H. J. (2025). Labor Analgesia Initiation with Dural Puncture Epidural versus Standard Epidural Techniques: A Prospective Randomized Dose Allocation Study of Ropivacaine. Drug Design, Development and Therapy. https://doi.org/10.2147/dddt.s547879

Vancouver

Xiao F, Drzymalski DM, Dong YF, Huang JY, Gao Y, Yan HY, et al. Labor Analgesia Initiation with Dural Puncture Epidural versus Standard Epidural Techniques: A Prospective Randomized Dose Allocation Study of Ropivacaine. Drug Design, Development and Therapy. 2025. doi:10.2147/dddt.s547879

BibTeX
@article{Xiao2025,
  author = {Xiao, Fei and Drzymalski, Dan M and Dong, Yu-Fang and Huang, Jia-Yue and Gao, Yan and Yan, Hai-Ya and Hu, Hui-Jing},
  title = {Labor Analgesia Initiation with Dural Puncture Epidural versus Standard Epidural Techniques: A Prospective Randomized Dose Allocation Study of Ropivacaine},
  journal = {Drug Design, Development and Therapy},
  year = {2025},
  doi = {10.2147/dddt.s547879}
}
Kostenlos starten →