Determination the ED90s of Different Concentrations of Initial Ropivacaine Volume for Labor Analgesia with Dural Puncture Epidural: A Randomized Sequential Allocation Study
Drug Design, Development and Therapy · 2025
DOI: 10.2147/dddt.s544672 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Drug Design, Development and Therapy, 2025. Verfasst von Meijuan Sun und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic …. Hauptthemen laut MEDLINE: Analgesia, Epidural, Analgesia, Obstetrical, Anesthetics, Local, Ropivacaine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Background
This study aims to determine the 90% effective doses (ED90) of the initial ropivacaine volume at varying concentrations (0.075%, 0.1%, 0.125%) administered under dural puncture epidural (DPE) for epidural labor analgesia.
Methods
Ninety ASA II-class patients with cervical dilation 5 were allocated into three groups (0.075%, 0.1%, and 0.125% ropivacaine concentrations) for epidural labor analgesia. The first patient in each group received an initial bolus of ropivacaine combined with sufentanil 0.3 µg/mL in a 10 mL volume. Subsequent doses were determined by an up-and-down sequential allocation method based on adequate analgesia (VAS score
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
- Department of Anesthesiology and Perioperative Medicine, General Hospital of Ningxia Medical University, Yinchuan, People's Republic of China.
ORCID-Profile: Yi Chen, Xiangsheng Xiong
Zitieren
APA
Sun, M., Chen, Y., Sun, L., Deng, Y., Xu, X., Zhang, L., & Xiong, X. (2025). Determination the ED90s of Different Concentrations of Initial Ropivacaine Volume for Labor Analgesia with Dural Puncture Epidural: A Randomized Sequential Allocation Study. Drug Design, Development and Therapy. https://doi.org/10.2147/dddt.s544672
Vancouver
Sun M, Chen Y, Sun L, Deng Y, Xu X, Zhang L, et al. Determination the ED90s of Different Concentrations of Initial Ropivacaine Volume for Labor Analgesia with Dural Puncture Epidural: A Randomized Sequential Allocation Study. Drug Design, Development and Therapy. 2025. doi:10.2147/dddt.s544672
BibTeX
@article{Sun2025,
author = {Sun, Meijuan and Chen, Yi and Sun, Linsen and Deng, Yu and Xu, Xiaoxiao and Zhang, Liang and Xiong, Xiangsheng},
title = {Determination the ED90s of Different Concentrations of Initial Ropivacaine Volume for Labor Analgesia with Dural Puncture Epidural: A Randomized Sequential Allocation Study},
journal = {Drug Design, Development and Therapy},
year = {2025},
doi = {10.2147/dddt.s544672}
}
EUVIMED