The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography
Cancer Management and Research · 2024-08 · Volume 16 · 1013-1020
DOI: 10.2147/cmar.s473653 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancer Management and Research, 2024-08. Verfasst von Savaş Gegin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Samsun Training and Research Hospital, Pulmonology Clinic, Samsun, Türkiye. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Aim
In cases where standardized maximum uptake (SUVmax) values in positron emission tomography (PET-CT) were not sufficient to differentiate mediastinal lymphadenopathy and masses from malignant or benign, the contribution of Hounsfield unit (HU) values in thorax computed tomography to the diagnosis was evaluated. Material Method: The study was conducted by evaluating the data of 182 patients between 2019 and 2023. HU values on non-contrast thorax computed tomography and PET-CT SUVmax values of biopsied masses and lymph nodes were compared with histopathological diagnoses.
Results
Patients, 58 females (31.9%) and 124 males (68.1%), who underwent EBUS were included in the study. Biopsies were taken from 233 stations (199 lymph nodes, 34 masses) from 182 patients. A total of 135 of the biopsies taken from 233 stations were histopathologically malignant and 98 were benign. While PET-CT SUVmax values of cases with benign histopathology were 4.5 ± 3.5, it was 7.6 ± 4.2 in patients with malignant pathology (p 0.05). When HU was compared according to lung cancer type, it was found to be significantly higher in non-small cell lung cancer (p=0.035). A weak (r=0.182) positive and significant relationship (p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Samsun Training and Research Hospital, Pulmonology Clinic, Samsun, Türkiye.
- Tokat Gaziosmanpaşa University, Faculty of Medicine, Department of Pulmonary Diseases, Tokat, Türkiye.
- Samsun University Faculty of Medicine, Pulmonology Department, Samsun, Türkiye.
ORCID-Profile: Savaş Gegin, Ahmet Cemal Pazarlı, Burcu Özdemir, Levent Özdemir, Esra Arslan Aksu
Zitieren
APA
Gegin, S., Pazarlı, A. C., Özdemir, B., Özdemir, L., & Aksu, E. A. (2024). The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography. Cancer Management and Research, Volume 16, 1013-1020. https://doi.org/10.2147/cmar.s473653
Vancouver
Gegin S, Pazarlı AC, Özdemir B, Özdemir L, Aksu EA. The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography. Cancer Management and Research. 2024;Volume 16:1013-1020. doi:10.2147/cmar.s473653
BibTeX
@article{Gegin2024,
author = {Gegin, Savaş and Pazarlı, Ahmet Cemal and Özdemir, Burcu and Özdemir, Levent and Aksu, Esra Arslan},
title = {The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography},
journal = {Cancer Management and Research},
year = {2024},
volume = {Volume 16},
pages = {1013--1020},
doi = {10.2147/cmar.s473653}
}
EUVIMED