EUVIMEDEUVIMED entdecken
Crossref

Certifying Regime Detectors Before Use

Diego Urdaneta Achong, Claudio Martel Flores, Melis Boztosun, Everett Zhang

SSRN Electronic Journal · 2026

DOI: 10.2139/ssrn.7100358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SSRN Electronic Journal, 2026. Verfasst von Diego Urdaneta Achong und 3 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Value-at-risk forecasts are backtested before they are trusted; regime detectors, whose labels and triggers enter inference and allocation just as directly, face no analogous pre-use validation. We propose one. A certication protocol treats a frozen detector as a measurement instrument and, for a single pre-declared claim, measures ve operating characteristics: power against a declared signal family (by controlled signal injection), false-alarm behavior under dependence-preserving resampled nulls, equivalence of outputs across calendar, volume, and event-time bars within a preregistered margin, detector-output information about the declared target, and the net value of that information under a declared cost convention. The protocol returns a certicate with a disposition and a gate-level failure prole, and refuses comparisons between detectors whose targets dier. We rst certify a Holm-corrected variance-ratio cascade on BTCUSDT one-minute perpetual futures (20212025; n = 2,415,148 bars) and withhold the verdict, for measured reasons: the cascade cannot detect variance-ratio departures ≤ 0.10 anywhere on the preregistered 96-cell grid; its nominal 5% rule produced zero false alarms in 100 null replicates, a size distortion traceable to a mis-centered asymptotic reference; cross-clock equivalence certies at q=2 but fails at the primary horizon q=5; and trigger information has a net value whose sign depends on the cost-attribution convention. We then show the diagnosis is actionable: recentering the decision statistic on the empirical null lowers the certied minimum detectable eect roughly tenfoldfrom 0.15 to 0.02 at q=2restores size control, and yields the protocol's rst admissible certicate, for a bounded and now adequately powered exclusion of positive short-horizon serial dependence. Casting each gate as an e-value makes admission anytime-valid: one product certicate bounds the probability of ever falsely admitting a detector, under optional stopping, with no error budget across gates or monitoring times. A three-family exhibit (rolling-quantile, hidden-Markov, variance-ratio) yields cost-dominated, instrumentfailed, and target-mismatched dispositionsfailure reasons no performance comparison reports. Every value traces to frozen, version-pinned artifacts, with conrmatory and exploratory provenance separated per table cell.

Zitieren

APA

Achong, D. U., Flores, C. M., Boztosun, M., & Zhang, E. (2026). Certifying Regime Detectors Before Use. SSRN Electronic Journal. https://doi.org/10.2139/ssrn.7100358

Vancouver

Achong DU, Flores CM, Boztosun M, Zhang E. Certifying Regime Detectors Before Use. SSRN Electronic Journal. 2026. doi:10.2139/ssrn.7100358

BibTeX
@article{Achong2026,
  author = {Achong, Diego Urdaneta and Flores, Claudio Martel and Boztosun, Melis and Zhang, Everett},
  title = {Certifying Regime Detectors Before Use},
  journal = {SSRN Electronic Journal},
  year = {2026},
  doi = {10.2139/ssrn.7100358}
}
Kostenlos starten →