Predicting Soluble Solids Concentration of ‘Geneva 3’ Kiwiberries Using Near Infrared Spectroscopy
HortTechnology · 2024-04 · 34 (2) · 172-180
DOI: 10.21273/horttech05316-23 ↗Kurz gefasst
Fachartikel in der Zeitschrift HortTechnology, 2024-04. Verfasst von Aislinn Mumford und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Near infrared (NIR) spectroscopy can be applied to nondestructively assess soluble solids concentration (SSC) of ripening, physiologically mature ‘Geneva 3’ kiwiberries ( Actinidia arguta ). Spectrographic signatures were captured using a handheld NIR produce quality meter to build predictive models of internal fruit quality for ‘Geneva 3’ kiwiberries that had been held under cold storage (CS) conditions (0 to 1 °C, >90% relative humidity) as well as those not subjected to CS. The CS model, constructed using scans of 133 berries following 4 to 6 weeks in CS, predicts SSC using NIR wavelengths in the range of 729 to 975 nm. A total of 507 berries fresh from the vine were used to construct a predictive model for SSC of non-CS fruit using the same wavelength range. In each case, model predictive performance was investigated using split-half cross-validation, resulting in mean absolute error (MAE) values of 1.2% and 0.8% SSC for the CS and non-CS model, respectively. Each full model was then used to predict SSC of kiwiberries subjected to the alternative CS condition. The non-CS model maintained a low MAE (1.6% SSC) when applied to CS fruit, but the MAE of the CS model applied to non-CS fruit rose considerably (4.5% SSC). The performance of a combined model was tested against both CS and non-CS models, and a benefit to using tailored, CS-specific models was found, particularly in light of cross-seasonal results. As it has proven in many crops, NIR spectroscopy appears to be a promising tool for nondestructively assessing SSC in ‘Geneva 3’ kiwiberry fruit, with accuracy being enhanced by training models specific to postharvest regimes and/or defined ranges of SSC.
Zitieren
APA
Mumford, A., Abrahamsson, Z., & Hale, I. (2024). Predicting Soluble Solids Concentration of ‘Geneva 3’ Kiwiberries Using Near Infrared Spectroscopy. HortTechnology, 34(2), 172-180. https://doi.org/10.21273/horttech05316-23
Vancouver
Mumford A, Abrahamsson Z, Hale I. Predicting Soluble Solids Concentration of ‘Geneva 3’ Kiwiberries Using Near Infrared Spectroscopy. HortTechnology. 2024;34(2):172-180. doi:10.21273/horttech05316-23
BibTeX
@article{Mumford2024,
author = {Mumford, Aislinn and Abrahamsson, Zachary and Hale, Iago},
title = {Predicting Soluble Solids Concentration of ‘Geneva 3’ Kiwiberries Using Near Infrared Spectroscopy},
journal = {HortTechnology},
year = {2024},
volume = {34},
number = {2},
pages = {172--180},
doi = {10.21273/horttech05316-23}
}
EUVIMED