Wireline Microfracture Test Implementation and Analysis Using the Diagnostic Fracture Injection Test-Flowback Analysis Procedure
SPE Journal · 01.11.2026 · 1-19
DOI: 10.2118/236995-pa ↗Kurz gefasst
Fachartikel in der Zeitschrift SPE Journal, online erschienen am 12.11.2026. Verfasst von C. R. Clarkson und 11 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben.
Abstract (Originalsprache)
Diagnostic fracture injection tests (DFITs) may be used to derive critical properties for evaluating caprocks and reservoirs in subsurface carbon dioxide (CO2) storage systems. These critical properties include minimum in-situ stress (used to assess maximum safe operating pressure for caprocks), pore pressure, and permeability (used to assess long-term containment for caprocks). Depending on the permeability of the caprock/reservoir, amongst other factors, pore pressure and permeability may require days or weeks to determine using a conventional (pump-in/shut-in) DFIT. An alternative DFIT, referred to as DFIT-FBA (with FBA being flowback analysis), may require much less time (generally 2–4 hours). The DFIT-FBA test sequence involves injection to start and propagate a minifracture (just like a conventional DFIT), followed by a brief shut-in period (used to evaluate near-well tortuosity effects), followed, in turn, by a short flowback period instead of a long shut-in period used for conventional DFITs. The flowback rates and pressures are analyzed using rate-transient analysis (RTA) to obtain critical properties. While conventional DFITs (and DFIT-FBA) are performed from surface through a vertical or horizontal wellbore drilled into the subsurface target, wireline-conveyed formation tests can be used to derive caprock/reservoir properties for isolated openhole intervals in vertical wells. Recently, a special version of a formation test (a microfracture test) was introduced to simulate pump-in/flowback cycles analogous to the flowback DFIT. In this study, a flowback microfracture test was designed, implemented, and analyzed using the DFIT-FBA procedure to obtain minimum in-situ stress, pore pressure, and permeability in a caprock for CO2 storage. The subject flowback microfracture test involved injection of ~0.004 m3 of filtered borehole mud into the caprock interval at an average rate of ~6×10−4 m3/min to create the microfracture, followed by an approximately constant flowback period (average rate ~ 5×10−5 m3/min) for 39 minutes. The created fracture area is estimated to be < 2 m2, compared with a typical DFIT-FBA-created fracture of < 1,000–3,000 m2. Because the test was performed in a small (1.19 m) isolated openhole interval of the well, wellbore storage and near-wellbore tortuosity (NWT) effects were negligible, removing some of the challenges associated with DFIT-FBA analysis. After smoothing the flowing pressure profile, a Cartesian flowing pressure vs. flowback time plot was used to estimate minimum in-situ stress. Following the DFIT-FBA procedure, pore pressure was estimated using both a Cartesian plot of flowing pressure vs. flowback time and a log-log plot of the integral of rate-normalized pressure vs. material balance time, while reservoir permeability was obtained using before-closure straightline (rate-transient) analysis (SLA). Permeability estimates from the flowback microfracture test are in reasonable agreement with that derived from petrophysical analysis [nuclear magnetic resonance (NMR) log] of the caprock. This proof-of-concept study demonstrates the utility of microfracture tests, combined with the DFIT-FBA testing and analysis procedure, to obtain rapid estimates of minimum in-situ stress, pore pressure, and permeability for low-permeability caprock systems.
Zitieren
APA
Clarkson, C. R., Haqparast, S., Naveena-Chandran, R., Batzer, C., Medina, R., Lopez, E., Hashmi, G., Hemsing, J., Mata, J., Hernandez, M., Lowrey, P., & Torgerson, S. (2026). Wireline Microfracture Test Implementation and Analysis Using the Diagnostic Fracture Injection Test-Flowback Analysis Procedure. SPE Journal, 1-19. https://doi.org/10.2118/236995-pa
Vancouver
Clarkson CR, Haqparast S, Naveena-Chandran R, Batzer C, Medina R, Lopez E, et al. Wireline Microfracture Test Implementation and Analysis Using the Diagnostic Fracture Injection Test-Flowback Analysis Procedure. SPE Journal. 2026:1-19. doi:10.2118/236995-pa
BibTeX
@article{Clarkson2026,
author = {Clarkson, C. R. and Haqparast, S. and Naveena-Chandran, R. and Batzer, C. and Medina, R. and Lopez, E. and Hashmi, G. and Hemsing, J. and Mata, J. and Hernandez, M. and Lowrey, P. and Torgerson, S.},
title = {Wireline Microfracture Test Implementation and Analysis Using the Diagnostic Fracture Injection Test-Flowback Analysis Procedure},
journal = {SPE Journal},
year = {2026},
pages = {1--19},
doi = {10.2118/236995-pa}
}
EUVIMED