EUVIMEDEUVIMED entdecken
Crossref

Testing an Improved Method to Determine Inaccessible Pore Volume

R. S. Seright

SPE Journal · 11.11.2026 · 31 (11) · 7890-7904

DOI: 10.2118/231509-pa ↗

Kurz gefasst

Fachartikel in der Zeitschrift SPE Journal, online erschienen am 03.09.2026. Verfasst von R. S. Seright. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Inaccessible pore volume (IAPV) is intended to characterize the fraction of aqueous pore space in a porous medium that is not accessible to flowing polymer. Previous IAPV literature is contradictory in that no correlation is evident between measured IAPV values and rock permeability or porosity or polymer molecular weight (Mw) or size in solution. Prior work by Gilman and MacMillan (1987) and Wang et al. (2020) demonstrated that much of the previous contradictory reports may result from the inadequacies of methods to measure IAPV. In particular, the “double-polymer/tracer bank” method incorporates a water flush between two polymer/tracer banks. The unfavorable mobility ratio as water displaces the second polymer bank causes viscous fingering and overestimation of IAPV if insufficient water is flushed. [At least 100 pore volumes (PV) of water may be needed for an adequate flush, depending on the water/polymer mobility ratio.] Dean et al. (2022) proposed a potentially improved method to determine IAPV, where a low-concentration polymer bank is displaced by a more-concentrated, more-viscous polymer bank—so the mobility ratio is always favorable during the displacement. The aim of this study is to test this method for determining IAPV. The tests performed for this study used sandstone cores and bead packs with permeabilities ranging from 113 md to 18,600 md, porosities ranging from 0.188 to 0.402, and core lengths ranging from 30.48 cm to 122 cm. Many tests involved 500-ppm partially hydrolyzed polyacrylamide [HPAM; with no potassium iodide (KI) tracer] displacing 250-ppm HPAM (with a KI tracer). However, three sets of the tests made five replicate determinations of IAPV using successive polymer banks with HPAM concentrations starting at 62.5 ppm and doubling in stages to 2,000 ppm. This procedure tested the reproducibility of the method and whether the IAPV measurement depended on HPAM concentration. With a given data set, multiple methods can be used to assign an IAPV value, including (1) the area between the polymer and tracer breakout curves, (2) the difference in PV throughput (between polymer and tracer) upon attaining an effluent concentration of 50% of the injected concentration, and (3) the difference in PV during the first breakout of polymer ahead of tracer. Significant differences in calculated IAPV values were noted for these different methods. In general, the method of Dean et al. (2022) provides a substantial improvement over previous methods when measuring IAPV. However, caution must be exercised when interpreting the results of these tests with respect to projecting polymer-flood performance. Important uncertainties arise from assessments of IAPV—notably, in rock with permeability above 200 md. These uncertainties arise partly because polymer retention can vary with polymer concentration—violating a key assumption of the method of Dean et al. From this work, it is arguable whether a significant IAPV exists in Berea sandstone or bead packs with permeability greater than 200 md (when using 18–20-million g/mol HPAM).

Zitieren

APA

Seright, R. S. (2026). Testing an Improved Method to Determine Inaccessible Pore Volume. SPE Journal, 31(11), 7890-7904. https://doi.org/10.2118/231509-pa

Vancouver

Seright RS. Testing an Improved Method to Determine Inaccessible Pore Volume. SPE Journal. 2026;31(11):7890-7904. doi:10.2118/231509-pa

BibTeX
@article{Seright2026,
  author = {Seright, R. S.},
  title = {Testing an Improved Method to Determine Inaccessible Pore Volume},
  journal = {SPE Journal},
  year = {2026},
  volume = {31},
  number = {11},
  pages = {7890--7904},
  doi = {10.2118/231509-pa}
}
Kostenlos starten →