EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ten to 15-Year Outcomes of Monoblock Uncemented Dual Mobility Cups

10- bis 15-Jahres-Ergebnisse von monoblock unzementierten Dual-Mobility-Cups

Cécile Batailler iD, Sébastien Lustig, Emmanuel Balot, Frédéric Farizon, Michel Henri Fessy, Rémi Philippot

JBJS Open Access · 2025-01 · 10 (1)

DOI: 10.2106/jbjs.oa.24.00074 ↗

Auf einen Blick

In einer retrospektiven Multizenterstudie zeigten monoblock unzementierte Dual-Mobility-Cups nach primärer Hüftarthroplastik sehr gute Langzeitergebnisse mit niedriger Luxationsrate.

Fragestellung

Wie sind Langzeitüberleben und funktionelle Ergebnisse eines modernen monoblock unzementierten Dual-Mobility-Cups bei primärer Hüftarthroplastik?

Methode

Retrospektive Multizenterstudie; 614 primäre THA mit demselben unzementierten monoblock DMC (2007–2010); Nachbeobachtung mindestens 10 Jahre; Kaplan-Meier-Analyse und Harris hip score.

Ergebnisse

572 THA für die Überlebensanalyse, 394 für die klinische Analyse. Cup-Revision-freies Überleben 98,6 % nach 10 Jahren und 96,2 % nach 13 Jahren. 3 Luxationen (0,52 %); Harris hip score 54,1 ± 14,4 vor OP und 88,0 ± 14,3 beim letzten Follow-up.

Schlussfolgerung der Autor:innen

Der monoblock unzementierte DMC zeigte ausgezeichnete Überlebensraten ohne DMC-spezifische Komplikationen in mindestens 10 Jahren Nachbeobachtung. Die Luxationsrate war sehr niedrig; ein jüngeres Alter war kein Risikofaktor für ein Versagen.

Kernaussagen

  • Cup-Revision-freies Überleben: 98,6 % nach 10 Jahren
  • 3 Luxationen (0,52 %), keine Revision wegen Luxation
  • Harris hip score verbesserte sich von 54,1 auf 88,0

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift JBJS Open Access, 2025-01. Verfasst von Cécile Batailler und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Croix-Rousse Hospital, Lyon, France. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dual mobility cups (DMCs) have effectively prevented dislocations after total hip arthroplasty (THA). However, use of these cups in primary THAs remains controversial, especially in young patients. This study aimed to determine the long-term survival rate and functional outcomes of a contemporary DMC used in primary THA.

Methods

This retrospective multicenter study identified a cohort of 614 primary THAs performed with the same uncemented monoblock DMC between 2007 and 2010. Survival analysis included 572 THAs, while clinical analysis involved 394 THAs at a minimal follow-up of 10 years. The mean follow-up was 11.1 ± 1.2 years. The mean age was 71.4 ± 11.7 years, with 4.2% of patients under 50 years old. The mean body mass index was 27.0 ± 5.3 kg/m 2 . The 10-year Kaplan-Meier survival rate was calculated based on cup removal for any reason or cup revision for an aseptic reason as the end point. Harris hip scores were collected at the last follow-up.

Results

The cup-revision-free survival rate was 98.6% at 10 years and 96.2% at 13 years. No cup revisions were reported due to aseptic loosening or dislocation. The cup revisions were due to infection (7 of 572; 1.2%), acetabular fracture (1 of 572; 0.17%), and psoas impingement due to cup malpositioning (n = 1 of 572; 0.17%). Only 3 dislocations (0.52%) were observed, and they did not require revision. The mean Harris hip score significantly improved from 54.1 ± 14.4 preoperatively to 88.0 ± 14.3 at the last follow-up (p < 0.0001). For patients under 50 years old at the time of surgery, the mean Harris hip score showed significant improvement from 53.0 ± 10.2 preoperatively to 89.7 ± 12.8 at the last follow-up (p < 0.0001), with no significant difference compared with the older patients (p = 0.50). No revision or complication was reported in the younger patient population at 13 years of follow-up.

Conclusions

The monoblock uncemented DMC demonstrated excellent survival rates with no DMC-specific complications during a minimum 10-year follow-up. The dislocation rate was very low, and a younger age was not identified as a risk factor for failure. Therefore, monoblock cementless DMCs can be safely used, even in primary THA. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Croix-Rousse Hospital, Lyon, France.
  • Université Claude Bernard Lyon 1, Université de Lyon, IFSTTAR, Villeurbanne, France.
  • Department of Orthopedic Surgery, Central Hospital University (CHU) Dijon Bourgogne, Dijon, France.
  • Department of Orthopedic Surgery, Saint Etienne University Hospital, Saint-Priest-en-Jarez, France.
  • Department of Orthopedic Surgery, Lyon Sud Hospital, Oullins-Pierre-Bénite, France.

ORCID-Profile: Cécile Batailler

Zitieren

APA

Batailler, C., Lustig, S., Balot, E., Farizon, F., Fessy, M. H., & Philippot, R. (2025). Ten to 15-Year Outcomes of Monoblock Uncemented Dual Mobility Cups. JBJS Open Access, 10(1). https://doi.org/10.2106/jbjs.oa.24.00074

Vancouver

Batailler C, Lustig S, Balot E, Farizon F, Fessy MH, Philippot R. Ten to 15-Year Outcomes of Monoblock Uncemented Dual Mobility Cups. JBJS Open Access. 2025;10(1). doi:10.2106/jbjs.oa.24.00074

BibTeX
@article{Batailler2025,
  author = {Batailler, Cécile and Lustig, Sébastien and Balot, Emmanuel and Farizon, Frédéric and Fessy, Michel Henri and Philippot, Rémi},
  title = {Ten to 15-Year Outcomes of Monoblock Uncemented Dual Mobility Cups},
  journal = {JBJS Open Access},
  year = {2025},
  volume = {10},
  number = {1},
  doi = {10.2106/jbjs.oa.24.00074}
}
Kostenlos starten →