Intraoperative Dysrhythmias Cease After Venting During Intramedullary Nailing of an Impending Femur Fracture
JBJS Case Connector · 2023
DOI: 10.2106/jbjs.cc.22.00126 ↗Kurz gefasst
Fallbericht in der Zeitschrift JBJS Case Connector, 2023. Verfasst von Frank A Martinez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Mayo Clinic Alix School of Medicine, Mayo Clinic, Rochester, Minnesota. Hauptthemen laut MEDLINE: Fracture Fixation, Intramedullary, Femoral Fractures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
Case: A 76-year-old woman with multiple myeloma and osteoporosis presented with right hip pain and an impending atypical femoral fracture in the setting of chronic bisphosphonate use. After preoperative medical optimization, she was scheduled for prophylactic intramedullary nail fixation. Intraoperatively, the patient experienced episodes of severe bradycardia and asystole associated with intramedullary reaming, which ceased after distal venting of the femur. No additional intraoperative or postoperative complications were encountered, and the patient recovered uneventfully. Conclusion: Femoral canal venting may be an appropriate intervention for similar transient dysrhythmias caused by intramedullary reaming.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Mayo Clinic Alix School of Medicine, Mayo Clinic, Rochester, Minnesota.
- Department of Orthopedic Surgery, Mayo Clinic, Rochester Minnesota.
- Department of Anesthesiology, Mayo Clinic, Rochester Minnesota.
ORCID-Profile: Frank A Martinez, Evan M Dugdale, Ryan E Hofer, Stephen A Sems
Zitieren
APA
Martinez, F. A., Dugdale, E. M., Sims, C. R., Hofer, R. E., & Sems, S. A. (2023). Intraoperative Dysrhythmias Cease After Venting During Intramedullary Nailing of an Impending Femur Fracture. JBJS Case Connector. https://doi.org/10.2106/jbjs.cc.22.00126
Vancouver
Martinez FA, Dugdale EM, Sims CR, Hofer RE, Sems SA. Intraoperative Dysrhythmias Cease After Venting During Intramedullary Nailing of an Impending Femur Fracture. JBJS Case Connector. 2023. doi:10.2106/jbjs.cc.22.00126
BibTeX
@article{Martinez2023,
author = {Martinez, Frank A and Dugdale, Evan M and Sims, Charles R and Hofer, Ryan E and Sems, Stephen A},
title = {Intraoperative Dysrhythmias Cease After Venting During Intramedullary Nailing of an Impending Femur Fracture},
journal = {JBJS Case Connector},
year = {2023},
doi = {10.2106/jbjs.cc.22.00126}
}
EUVIMED