Antibiotic-Loaded Ceramic Bone Grafts Exhibit Burst, Not Sustained, Gentamicin Release
Journal of Bone and Joint Surgery · 17.08.2026
DOI: 10.2106/jbjs.26.00470 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bone and Joint Surgery, online erschienen am 17.08.2026. Verfasst von Catrine Jyde Berthelsen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Section for Cell and Drug Technologies, Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
Antibiotic-loaded ceramic bone grafts (ACBGs) are widely assumed to provide extended local antimicrobial protection, maintaining concentrations above the minimum inhibitory concentration (MIC) for 28 to 42 days. However, this time frame is mainly based on in vitro elution assays with simplified washout models, and its relevance to in vivo performance is uncertain. This study compared the in vivo and in vitro release and behavior of gentamicin from 2 commercial ACBGs.
Methods
Gentamicin-loaded hydroxyapatite/calcium sulfate (HA-CS) and calcium sulfate (CS) composites were investigated using a murine implantation model and in vitro elution assays. Gentamicin content in recovered depot material and elution media was quantified by liquid chromatography with tandem mass spectrometry. Model calculations evaluated how the assay design affects the estimated time above the MIC.
Results
Both ACBGs released >98% of gentamicin within 6 hours and >99% within 24 hours in vivo. In vitro assays likewise indicated early depot depletion, with concentration-time profiles beyond 48 hours driven by serial dilution rather than release. Model calculations suggested that the apparent prolonged antibiotic activity in previous in vitro assays was largely due to the assay design, not to sustained release, implying that freely administered antibiotics could produce similar profiles.
Conclusions
Neither ACBG demonstrated measurable sustained release beyond an initial 24-hour burst phase. This may have important clinical implications, as expectations of prolonged local antimicrobial protection are not supported by the cumulative-release data showing rapid antibiotic depot depletion.
Autor:innen und Institutionen
- Section for Cell and Drug Technologies, Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark.
- Department of Plant and Environmental Sciences, Faculty of Science, University of Copenhagen, Frederiksberg, Denmark.
- Department of Veterinary and Animal Sciences, University of Copenhagen, Frederiksberg, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark.
ORCID-Profile: Catrine Jyde Berthelsen, Christoph Crocoll, Michal Poborsky, Louise Kruse Jensen, Jonas Rosager Henriksen, Anders Elias Hansen, Mats Bue
Zitieren
APA
Berthelsen, C. J., Crocoll, C., Poborsky, M., Jensen, L. K., Henriksen, J. R., Hansen, A. E., & Bue, M. (2026). Antibiotic-Loaded Ceramic Bone Grafts Exhibit Burst, Not Sustained, Gentamicin Release. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.26.00470
Vancouver
Berthelsen CJ, Crocoll C, Poborsky M, Jensen LK, Henriksen JR, Hansen AE, et al. Antibiotic-Loaded Ceramic Bone Grafts Exhibit Burst, Not Sustained, Gentamicin Release. Journal of Bone and Joint Surgery. 2026. doi:10.2106/jbjs.26.00470
BibTeX
@article{Berthelsen2026,
author = {Berthelsen, Catrine Jyde and Crocoll, Christoph and Poborsky, Michal and Jensen, Louise Kruse and Henriksen, Jonas Rosager and Hansen, Anders Elias and Bue, Mats},
title = {Antibiotic-Loaded Ceramic Bone Grafts Exhibit Burst, Not Sustained, Gentamicin Release},
journal = {Journal of Bone and Joint Surgery},
year = {2026},
doi = {10.2106/jbjs.26.00470}
}
EUVIMED