EUVIMEDEUVIMED entdecken
Crossref

Operative Fires

Bryce Hendrix iD, Brent Ponce, Aaron Joiner, Cole Connelley iD, Tyler Kelly iD, Randall Ruark iD

Journal of Bone and Joint Surgery · 2025

DOI: 10.2106/jbjs.24.00558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bone and Joint Surgery, 2025. Verfasst von Bryce Hendrix und 5 weiteren Autor:innen. Beteiligte Einrichtung: Jack Hughston Memorial Hospital, Phenix City, Alabama. Hauptthemen laut MEDLINE: Polymethyl Methacrylate, Fires, Operating Rooms, Electrocoagulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Operative fires are rare but unforgettable events, with the potential for devastating outcomes. It is estimated that 650 operating room (OR) fires occur each year in the United States, with the use of electrocautery devices and polymethylmethacrylate (PMMA) as the primary ignition and fuel sources. There are several case reports of OR fires caused by PMMA and electrocautery in the literature, but, to our knowledge, no formal studies have been performed exposing the flammability of PMMA and how PMMA reacts to an electrocautery ignition source.

Methods

We studied the flammability of PMMA with electrocautery as an ignition source in a controlled laboratory setting. We used 2 different brands of PMMA, both with and without antibiotics. The PMMA was prepared according to the manufacturer’s guidelines. In our model, which used a cadaveric leg, the PMMA was placed next to a femoral component that is used in total knee arthroplasty (TKA). Electrocautery was applied at 30-second intervals for a total of 15 minutes. Flammability was defined as any visualized spark or flame while using an electrocautery device. The heat resulting from the chemical reaction was recorded every 30 seconds with a thermal imaging camera (TIC). Video recording was used during the experiment to document the flammability events. A total of 108 tests were performed.

Results

PMMA with and without antibiotics proved to be flammable with the use of electrocautery. All flammability occurred within 7 minutes of combining the monomer and the powder. Increased flammability was seen with the use of antibiotic additives.

Conclusions

PMMA was found to be highly flammable in the initial curing period when exposed to electrocautery as an ignition source. When PMMA is ready for application, we recommend that an “electrocautery timeout” be performed, wherein the electrocautery device is removed from the operating field for a minimum of 7 minutes or until the PMMA has fully hardened.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polymethyl MethacrylateFiresOperating RoomsElectrocoagulationBone CementsHumansArthroplasty, Replacement, Knee

Substanzen

Polymethyl MethacrylateBone Cements

Autor:innen und Institutionen

  • Jack Hughston Memorial Hospital, Phenix City, Alabama.
  • Jack Hughston Foundation, Columbus, Georgia.

ORCID-Profile: Bryce Hendrix, Cole Connelley, Tyler Kelly, Randall Ruark

Zitieren

APA

Hendrix, B., Ponce, B., Joiner, A., Connelley, C., Kelly, T., & Ruark, R. (2025). Operative Fires. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.24.00558

Vancouver

Hendrix B, Ponce B, Joiner A, Connelley C, Kelly T, Ruark R. Operative Fires. Journal of Bone and Joint Surgery. 2025. doi:10.2106/jbjs.24.00558

BibTeX
@article{Hendrix2025,
  author = {Hendrix, Bryce and Ponce, Brent and Joiner, Aaron and Connelley, Cole and Kelly, Tyler and Ruark, Randall},
  title = {Operative Fires},
  journal = {Journal of Bone and Joint Surgery},
  year = {2025},
  doi = {10.2106/jbjs.24.00558}
}
Kostenlos starten →