Association of Technology Usage and Decreased Revision TKA Rates for Low-Volume Surgeons Using an Optimal Prosthesis Combination
Journal of Bone and Joint Surgery · 2024
DOI: 10.2106/jbjs.24.00539 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bone and Joint Surgery, 2024. Verfasst von Michael McAuliffe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, South Australia, Australia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Reoperation, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
Background
Technology (navigation and robotics) usage during total knee arthroplasty (TKA) is often supported by literature involving high-volume surgeons and hospitals, but the value of technology for lower-volume surgeons is uncertain. This study aimed to determine if there was a relationship among surgeon volume, technology usage, and revision rate when using an optimal prosthesis combination (OPC).
Methods
Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) data were obtained from January 1, 2008, to December 31, 2022, for all primary TKA procedures performed for osteoarthritis using an OPC by a known surgeon ≥5 years after their first recorded procedure. The interaction between surgeon volume and conventional-instrumentation (CV) versus technology-assisted (TA) TKA was assessed. The cumulative percent revision (CPR) was determined by Kaplan-Meier estimates. Cox proportional-hazards methods were used to compare rates of revision by surgeon volume and by the interaction of volume and technology. Subanalyses were undertaken to examine major and minor revisions separately, and to assess the influence of technology on revision rates relative to those of a surgeon undertaking 100 TKA/year.
Results
Of the 53,264 procedures that met the inclusion criteria, 31,536 were TA-TKA and 21,728 were CV-TKA. Use of technology reduced the all-cause revision rate for surgeons with a volume of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, South Australia, Australia.
- Queensland University of Technology, Brisbane, Queensland, Australia.
- CJM Centre, Ipswich, Queensland, Australia.
- Sydney Orthopaedic Research Institute, Sydney, New South Wales, Australia.
- Brisbane Orthopaedic and Sports Medicine Centre (BOSMC), Brisbane, Queensland, Australia.
- School of Human Movement and Nutrition Sciences, University of Queensland, St Lucia, Queensland, Australia.
ORCID-Profile: Ibrahim Darwish
Zitieren
APA
McAuliffe, M., Darwish, I., Anderson, J., Nicholls, A., Corfield, S., Harries, D., & Vertullo, C. (2024). Association of Technology Usage and Decreased Revision TKA Rates for Low-Volume Surgeons Using an Optimal Prosthesis Combination. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.24.00539
Vancouver
McAuliffe M, Darwish I, Anderson J, Nicholls A, Corfield S, Harries D, et al. Association of Technology Usage and Decreased Revision TKA Rates for Low-Volume Surgeons Using an Optimal Prosthesis Combination. Journal of Bone and Joint Surgery. 2024. doi:10.2106/jbjs.24.00539
BibTeX
@article{McAuliffe2024,
author = {McAuliffe, Michael and Darwish, Ibrahim and Anderson, Jon and Nicholls, Alex and Corfield, Sophie and Harries, Dylan and Vertullo, Christopher},
title = {Association of Technology Usage and Decreased Revision TKA Rates for Low-Volume Surgeons Using an Optimal Prosthesis Combination},
journal = {Journal of Bone and Joint Surgery},
year = {2024},
doi = {10.2106/jbjs.24.00539}
}
EUVIMED