A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections
Journal of Bone and Joint Surgery · 2023
DOI: 10.2106/jbjs.23.00532 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Bone and Joint Surgery, 2023. Verfasst von Andreas G Tsantes und 14 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Haematology and Blood Bank Unit, Attikon Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Arthroplasty, Replacement, Hip, Arthritis, Infectious, Hemostatics. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
Periprosthetic joint infections (PJIs) are associated with altered hemostatic dynamics; therefore, coagulation laboratory methods such as rotational thromboelastometry (ROTEM) may be valuable in their diagnosis. The aim of this study was to evaluate the diagnostic role of ROTEM in PJI.
Methods
A diagnostic study was conducted including 65 patients who underwent revision total hip arthroplasty or total knee arthroplasty due to PJI (30 patients) or aseptic loosening (35 patients). Preoperative laboratory evaluation included conventional coagulation studies, inflammatory markers, and ROTEM analysis. These parameters were compared between patients with PJI and patients with aseptic loosening.
Results
Several ROTEM parameters differed in the patients with PJI, indicating a higher coagulation potential associated with PJI. Specifically, the development of PJI was associated with higher EXTEM maximum clot firmness (MCF) (odds ratio [OR], 1.12 [95% confidence interval (CI), 1.04 to 1.20]; p = 0.001). Among the ROTEM parameters, EXTEM MCF was found to have the highest diagnostic accuracy for PJI (area under the receiver operating characteristic curve, 0.850; sensitivity, 76.6%; specificity, 91.4%), which was comparable with C-reactive protein (CRP) (p = 0.22) and erythrocyte sedimentation rate (ESR) (p = 0.65), but higher than D-dimer (p = 0.037). Moreover, the combined diagnostic accuracy of elevated EXTEM MCF and CRP was improved compared with CRP alone (p = 0.019).
Conclusions
Our results indicate that ROTEM analysis might be helpful for the detection of the hemostatic derangements that are associated with the development of PJI. However, because of the small size of this pilot study, further research is needed to investigate the value of incorporating viscoelastic studies in diagnostic scores for PJI. Level of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Laboratory of Haematology and Blood Bank Unit, Attikon Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
- Microbiology Department, Saint Savvas Oncology Hospital, Athens, Greece.
- Second Department of Orthopaedics, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
- First Department of Orthopaedics, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
- Laboratory of Reliability and Quality Control in Laboratory Hematology, Department of Biomedical Sciences, School of Health & Caring Sciences, University of West Attica, Egaleo, Greece.
- Department of Hygiene and Epidemiology, University of Ioannina Medical School, Ioannina, Greece.
Zitieren
APA
Tsantes, A. G., Papadopoulos, D. V., Goumenos, S., Trikoupis, I. G., Tsante, K. A., Bellou, V., Koulouvaris, P., Houhoula, D., Kriebardis, A., Piovani, D., Nikolopoulos, G. K., Mavrogenis, A. F., Papagelopoulos, P. J., Bonovas, S., & Tsantes, A. E. (2023). A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.23.00532
Vancouver
Tsantes AG, Papadopoulos DV, Goumenos S, Trikoupis IG, Tsante KA, Bellou V, et al. A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections. Journal of Bone and Joint Surgery. 2023. doi:10.2106/jbjs.23.00532
BibTeX
@article{Tsantes2023,
author = {Tsantes, Andreas G and Papadopoulos, Dimitrios V and Goumenos, Stavros and Trikoupis, Ioannis G and Tsante, Konstantina A and Bellou, Vanesa and Koulouvaris, Panagiotis and Houhoula, Dimitra and Kriebardis, Anastasios and Piovani, Daniele and Nikolopoulos, Georgios K and Mavrogenis, Andreas F and Papagelopoulos, Panayiotis J and Bonovas, Stefanos and Tsantes, Argirios E},
title = {A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections},
journal = {Journal of Bone and Joint Surgery},
year = {2023},
doi = {10.2106/jbjs.23.00532}
}
EUVIMED