EUVIMEDEUVIMED entdecken
Evaluationsstudie

Accuracy Evaluation of a Novel Spinal Robotic System for Autonomous Laminectomy in Thoracic and Lumbar Vertebrae

Zhuofu Li iD, Chengxia Wang iD, Xiongkang Song iD, Shanshan Liu iD, Yonghong Zhang iD, Shuai Jiang iD, Xuquan Ji, Tianyang Zhang iD, Fei Xu iD, Lei Hu iD, Weishi Li iD

Journal of Bone and Joint Surgery · 2023

DOI: 10.2106/jbjs.22.01320 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Bone and Joint Surgery, 2023. Verfasst von Zhuofu Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Pedicle Screws, Robotic Surgical Procedures, Spinal Fusion, Surgery, Computer-Assisted. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The main function of robots in spine surgery is to assist with pedicle screw placement. Laminectomy, which is as important as pedicle screw placement, lacks a mature robot-assisted system. The aims of this study were to introduce the first autonomous laminectomy robot, to explore the feasibility of autonomous robotic laminectomy, and to validate its accuracy using a cadaveric model.

Methods

Forty vertebrae from 4 cadavers were included in the study; 7 thoracic and 3 lumbar vertebrae were randomly selected in each cadaver. The surgeon was able to plan the laminectomy path based on computed tomographic (CT) data before the surgical procedure. The robot performed the laminectomy autonomously, and a postoperative CT scan was made. The deviation of each cutting plane from the plan was quantitatively analyzed, and the accuracy and safety were qualitatively evaluated. The time required for the laminectomy was also recorded.

Results

Cuts were performed in 80 laminectomy planes (56 for thoracic vertebrae and 24 for lumbar vertebrae). The mean time for 1-sided laminectomy was 333.59 ± 116.49 seconds, which was shorter for thoracic vertebrae (284.41 ± 66.04 seconds) than lumbar vertebrae (448.33 ± 128.65 seconds) (p < 0.001). The mean time for single-level total laminectomy was 814.05 ± 302.23 seconds, which was also shorter for thoracic vertebrae (690.46 ± 165.74 seconds) than lumbar vertebrae (1,102.42 ± 356.13 seconds) (p = 0.002). The mean deviation of the cutting plane from the plan was 0.67 ± 0.30 mm for the most superior cutting point and 0.73 ± 0.31 mm for the most inferior point. There were no significant differences in the deviation between thoracic vertebrae (0.66 ± 0.26 mm) and lumbar vertebrae (0.67 ± 0.38 mm) at the superior cutting point (p = 0.908) and between thoracic vertebrae (0.72 ± 0.30 mm) and lumbar vertebrae (0.73 ± 0.33 mm) at the inferior cutting point (p = 0.923). In the qualitative analysis of the accuracy of the 80 laminectomy planes, 66 (83%) were classified as grade A, 14 (18%) were grade B, and none was grade C. In the safety analysis, 65 planes (81%) were considered safe and the safety of the other 15 planes (19%) was considered uncertain.

Conclusions

The results confirmed the accuracy of this robotic system, supporting its use for laminectomy of thoracolumbar vertebrae. Level of Evidence: Therapeutic Level V . See Instructions for Authors for a complete description of levels of evidence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pedicle ScrewsRobotic Surgical ProceduresSpinal FusionSurgery, Computer-AssistedHumansCadaverLaminectomyLumbar VertebraeThoracic Vertebrae

Autor:innen und Institutionen

  • Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China.
  • Beijing Key Laboratory of Spinal Disease Research, Beijing, People's Republic of China.
  • Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, People's Republic of China.
  • Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing, People's Republic of China.
  • Beijing Zhuzheng Robot Co., Ltd., Beijing, People's Republic of China.
  • School of Biological Science and Medical Engineering, Beihang University, Beijing, People's Republic of China.

ORCID-Profile: Zhuofu Li, Chengxia Wang, Xiongkang Song, Shanshan Liu, Yonghong Zhang, Shuai Jiang, Tianyang Zhang, Fei Xu, Lei Hu, Weishi Li

Zitieren

APA

Li, Z., Wang, C., Song, X., Liu, S., Zhang, Y., Jiang, S., Ji, X., Zhang, T., Xu, F., Hu, L., & Li, W. (2023). Accuracy Evaluation of a Novel Spinal Robotic System for Autonomous Laminectomy in Thoracic and Lumbar Vertebrae. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.22.01320

Vancouver

Li Z, Wang C, Song X, Liu S, Zhang Y, Jiang S, et al. Accuracy Evaluation of a Novel Spinal Robotic System for Autonomous Laminectomy in Thoracic and Lumbar Vertebrae. Journal of Bone and Joint Surgery. 2023. doi:10.2106/jbjs.22.01320

BibTeX
@article{Li2023,
  author = {Li, Zhuofu and Wang, Chengxia and Song, Xiongkang and Liu, Shanshan and Zhang, Yonghong and Jiang, Shuai and Ji, Xuquan and Zhang, Tianyang and Xu, Fei and Hu, Lei and Li, Weishi},
  title = {Accuracy Evaluation of a Novel Spinal Robotic System for Autonomous Laminectomy in Thoracic and Lumbar Vertebrae},
  journal = {Journal of Bone and Joint Surgery},
  year = {2023},
  doi = {10.2106/jbjs.22.01320}
}
Kostenlos starten →