Sprayable Ag@ZIF-8/graphene composite coating for antibacterial and antibiofilm applications in neonatal incubator water tanks
Translational Pediatrics · 2026-11 · 15 (11) · 447-447
DOI: 10.21037/tp-2026-0701 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Pediatrics, 2026-11. Verfasst von Ping Wang und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Nosocomial contamination of neonatal incubator water tanks poses a significant infection control challenge in neonatal intensive care units (NICUs). Traditional disinfection methods are insufficient to completely address biofilm related risks, highlighting the need for innovative functional coating materials for the surfaces of incubator tanks. This study aimed to fabricate and evaluate a sprayable Ag@ZIF-8/graphene siloxane composite coating for neonatal incubator water tank surfaces under static in vitro conditions over a 24–72 h period.
Methods
This study involved the fabrication and evaluation of an Ag@ZIF-8/graphene siloxane composite coating under static in vitro conditions over a 24–72 h period. The dry-state scratch critical load (Lc) was tested to assess the coating's interfacial adhesion. A structural hypothesis concerning Ag+ substitution within the zeolitic imidazolate framework-8 (ZIF-8) crystal lattice was proposed and discussed. The antibacterial activity and cytocompatibility were examined using Staphylococcus aureus, laboratory Escherichia coli, and L929 fibroblasts. Concentrations of released silver and zinc ions were quantified and compared with established safety reference thresholds.
Results
The cumulative concentrations of released silver and zinc ions stayed below the safety reference values reported in the literature. However, the lack of graphene-only, Ag-free, and metal-organic framework (MOF)-only control groups in this setup prevented full validation of the synergistic antibacterial mechanism. Despite this limitation, the preliminary in vitro data indicate the composite coating's potential application for NICU incubator surfaces.
Conclusions
Although this coating demonstrates promising initial performance in static laboratory conditions, further evaluations are essential before clinical application. These include long-term stability tests, dynamic-flow simulations, and testing with clinically relevant pathogens.
Zitieren
APA
Wang, P., Shen, S., Zheng, Y., Zhang, W., Shi, J., Guo, Z., Gao, X., Yang, W., & Niu, H. (2026). Sprayable Ag@ZIF-8/graphene composite coating for antibacterial and antibiofilm applications in neonatal incubator water tanks. Translational Pediatrics, 15(11), 447-447. https://doi.org/10.21037/tp-2026-0701
Vancouver
Wang P, Shen S, Zheng Y, Zhang W, Shi J, Guo Z, et al. Sprayable Ag@ZIF-8/graphene composite coating for antibacterial and antibiofilm applications in neonatal incubator water tanks. Translational Pediatrics. 2026;15(11):447-447. doi:10.21037/tp-2026-0701
BibTeX
@article{Wang2026,
author = {Wang, Ping and Shen, Silin and Zheng, Ya and Zhang, Wenyan and Shi, Jiaming and Guo, Zhimei and Gao, Xiaohong and Yang, Wei and Niu, Huixia},
title = {Sprayable Ag@ZIF-8/graphene composite coating for antibacterial and antibiofilm applications in neonatal incubator water tanks},
journal = {Translational Pediatrics},
year = {2026},
volume = {15},
number = {11},
pages = {447--447},
doi = {10.21037/tp-2026-0701}
}