Application of high-frequency ultrasound in the early detection of pressure injury and evaluation of decompression treatment
Quantitative Imaging in Medicine and Surgery · 2025-03 · 15 (3) · 2280-2295
DOI: 10.21037/qims-24-1612 ↗Kurz gefasst
Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2025-03. Verfasst von Rongchen Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Themen: Dekubitus
Abstract (Originalsprache)
Background
Pressure injury (PI) is an ischemic necrosis caused by long-term pressure on the local skin, which is common in the sacrococcygeal region of long-term bedridden patients. The main treatment for PI is decompression. The Braden scale is the primary clinical evaluation tool for PI, but it cannot quantitatively evaluate PI. High-frequency ultrasound (HFUS) can be used for the real-time quantitative evaluation of PI. This study used HFUS to qualitatively and quantitatively assess the soft tissues of the sacrococcygeal region in different risk PI groups to investigate any differences in HFUS manifestations and evaluate the efficacy of decompression treatment in stage 1 PI patients.
Methods
A total of 70 patients were recruited from the Intensive Care Unit at West China Hospital, Sichuan University, of whom, 28 were allocated to the case group (a moderate or higher risk for PI, and a Braden score of 15-17) and 42 were allocated to the control group (a very mild risk for PI, and a Braden score ≥18). HFUS was used to measure tissue thickness and ultrasonographic characteristics, as well as blood flow signals at 10 target sites along the transverse plane from the sacral protrusion to the top. Differences between groups were compared, and diagnostic efficacy was evaluated by a receiver operating characteristic (ROC) curve analysis, and the area under the curve (AUC) was calculated. A subgroup of 12 extremely high-risk patients receiving decompression treatment was also examined. The HFUS parameters were compared before and after treatment to evaluate efficacy.
Results
In the case group, ultrasonographic uneven echo, unclear boundaries between adipose/muscular layers and dermis/adipose layers, and discontinuous deep/superficial fascia were more common closer to sacral protrusions (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China.
Zitieren
APA
Wang, R., Tang, X., Qiu, L., & Wang, L. (2025). Application of high-frequency ultrasound in the early detection of pressure injury and evaluation of decompression treatment. Quantitative Imaging in Medicine and Surgery, 15(3), 2280-2295. https://doi.org/10.21037/qims-24-1612
Vancouver
Wang R, Tang X, Qiu L, Wang L. Application of high-frequency ultrasound in the early detection of pressure injury and evaluation of decompression treatment. Quantitative Imaging in Medicine and Surgery. 2025;15(3):2280-2295. doi:10.21037/qims-24-1612
BibTeX
@article{Wang2025,
author = {Wang, Rongchen and Tang, Xinyi and Qiu, Li and Wang, Liyun},
title = {Application of high-frequency ultrasound in the early detection of pressure injury and evaluation of decompression treatment},
journal = {Quantitative Imaging in Medicine and Surgery},
year = {2025},
volume = {15},
number = {3},
pages = {2280--2295},
doi = {10.21037/qims-24-1612}
}
EUVIMED