EUVIMEDEUVIMED entdecken
Open Access

Differentiating pulmonary embolism from contrast accumulation-induced beam hardening artifacts using dual-energy CT quantitative parameters

Qingle Wang, Heqing Wang, Chong Lin, Xu Huang, Suping Chen, Jinhui Zhang, Jinkui Pei, Zhiyong Zhang, Jianjun Zhou

Quantitative Imaging in Medicine and Surgery · 2025-06 · 15 (6) · 5593-5603

DOI: 10.21037/qims-24-1385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2025-06. Verfasst von Qingle Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

During computed tomography pulmonary angiography (CTPA) examination, contrast accumulation in the superior vena cava often generates beam hardening artifacts (BHAs), which can interfere with accurate diagnosis. This study aimed to investigate the diagnostic value of dual-energy computed tomography (DECT) quantitative parameters in differentiating pulmonary embolism (PE) from BHA.

Methods

A total of 68 patients with PE who underwent DE-CTPA were retrospectively included. Quantitative parameters [slope of Hounsfield unit (HU) curves (Slope), CT values on virtual monoenergetic images (VMIs) ranging from 40 to 100 keV (HU40 keV-HU100 keV), normalized iodine concentration (NIC), and normalized effective atomic number (NEffZ)] on the BHA-induced low-density area of the right upper pulmonary artery (artifact), embolism, and the corresponding normal area of the left upper or right middle pulmonary artery (normal) were measured and calculated. The parameters among the three groups were compared, and the performances of the parameters in differentiating the three conditions were evaluated.

Results

Quantitative parameters, including HU90 keV, HU100 keV, NIC, NeffZ, and Slope were all highest for normal arteries, followed by artifacts, and lowest for embolism (all P 0.05). Between normal and artifact, NIC showed the highest AUC (0.865), whereas multi-variables combining HU100 keV, NIC, and Slope improved the AUC to 0.937 and the model quality increased to 0.90 (P 0.05).

Conclusions

Quantitative parameters derived from DECT could recognize BHA in the superior vena cava; therein, 90 keV and 100 keV VMIs and their HU measurements would be particularly valuable.

Schlagwörter

Stichwörter der Autor:innen

Dual-energy computed tomography (DECT)beam hardening artifacts (BHAs)computed tomography pulmonary angiography (CTPA)contrast accumulationembolism

Autor:innen und Institutionen

  • Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Shanghai Institute of Medical Imaging, Shanghai, China.
  • Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China.
  • Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, China.
  • Department of Thoracic Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Computed Tomography Research Center, GE HealthCare, Changsha, China.

Zitieren

APA

Wang, Q., Wang, H., Lin, C., Huang, X., Chen, S., Zhang, J., Pei, J., Zhang, Z., & Zhou, J. (2025). Differentiating pulmonary embolism from contrast accumulation-induced beam hardening artifacts using dual-energy CT quantitative parameters. Quantitative Imaging in Medicine and Surgery, 15(6), 5593-5603. https://doi.org/10.21037/qims-24-1385

Vancouver

Wang Q, Wang H, Lin C, Huang X, Chen S, Zhang J, et al. Differentiating pulmonary embolism from contrast accumulation-induced beam hardening artifacts using dual-energy CT quantitative parameters. Quantitative Imaging in Medicine and Surgery. 2025;15(6):5593-5603. doi:10.21037/qims-24-1385

BibTeX
@article{Wang2025,
  author = {Wang, Qingle and Wang, Heqing and Lin, Chong and Huang, Xu and Chen, Suping and Zhang, Jinhui and Pei, Jinkui and Zhang, Zhiyong and Zhou, Jianjun},
  title = {Differentiating pulmonary embolism from contrast accumulation-induced beam hardening artifacts using dual-energy CT quantitative parameters},
  journal = {Quantitative Imaging in Medicine and Surgery},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {5593--5603},
  doi = {10.21037/qims-24-1385}
}
Kostenlos starten →