Evaluation of tubal patency based on peak injection pressure in four-dimensional hysterosalpingo-contrast sonography among infertile females: a preliminary study
Quantitative Imaging in Medicine and Surgery · 2024-05 · 14 (5) · 3461-3472
DOI: 10.21037/qims-23-1569 ↗Kurz gefasst
Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2024-05. Verfasst von Ling Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, West China Second Hospital of Sichuan University, Chengdu, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Although the application of four-dimensional hysterosalpingo-contrast sonography (4D-HyCoSy) has relatively good diagnostic accuracy for assessing the patency of the fallopian tubes, the evaluation process mainly relies on morphological findings of the fallopian tubes and pelvic cavity. The purpose of this study was to explore the relationship of peak injection pressure during 4D-HyCoSy and tubal patency to provide a quantitative indicator for the evaluation of fallopian tube patency.
Methods
This study included infertile patients who underwent 4D-HyCoSy and laparoscopic chromopertubation (LC) between 2020 and 2022, with LC serving as the reference test for assessing tubal patency. For the HyCoSy procedure, the ultrasound contrast agent was injected automatically using a liquid injection machine, and real-time pressure values were recorded. Patients were classified based on tubal patency status in LC as bilaterally patent, unilaterally patent, or bilaterally nonpatent. The average peak injection pressure and contrast agent volume of different groups were compared. Receiver operating characteristic (ROC) curve analysis was employed to determine the cutoff value.
Results
A total of 268 infertile patients were enrolled in the study. With LC as the standard examination, the sensitivity and specificity of 4D-HyCoSy in diagnosing nonpatent fallopian tubes were 91.1% and 95.1%, respectively. In general, peak injection pressure was observed to gradually increase as tubal patency decreased (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, West China Second Hospital of Sichuan University, Chengdu, China.
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University, Chengdu, China.
Zitieren
APA
Wang, L., Chen, X., He, M., Hu, S., Ren, Q., Qi, X., Tan, Y., & Luo, H. (2024). Evaluation of tubal patency based on peak injection pressure in four-dimensional hysterosalpingo-contrast sonography among infertile females: a preliminary study. Quantitative Imaging in Medicine and Surgery, 14(5), 3461-3472. https://doi.org/10.21037/qims-23-1569
Vancouver
Wang L, Chen X, He M, Hu S, Ren Q, Qi X, et al. Evaluation of tubal patency based on peak injection pressure in four-dimensional hysterosalpingo-contrast sonography among infertile females: a preliminary study. Quantitative Imaging in Medicine and Surgery. 2024;14(5):3461-3472. doi:10.21037/qims-23-1569
BibTeX
@article{Wang2024,
author = {Wang, Ling and Chen, Xin and He, Min and Hu, Sha and Ren, Quanlin and Qi, Xiaoying and Tan, Yifei and Luo, Hong},
title = {Evaluation of tubal patency based on peak injection pressure in four-dimensional hysterosalpingo-contrast sonography among infertile females: a preliminary study},
journal = {Quantitative Imaging in Medicine and Surgery},
year = {2024},
volume = {14},
number = {5},
pages = {3461--3472},
doi = {10.21037/qims-23-1569}
}