EUVIMEDEUVIMED entdecken
Open Access

A new formula based on new parameters for predicting postoperative vault after posterior chamber intraocular lens implantation: a retrospective study

Wei Cui, Xiaoming Wu, Qi Ren, Kun Liu, Fanqin Kong, Jie Wu

Quantitative Imaging in Medicine and Surgery · 2023-09 · 13 (9) · 5502-5510

DOI: 10.21037/qims-22-1425 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2023-09. Verfasst von Wei Cui und 5 weiteren Autor:innen. Beteiligte Einrichtung: Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China. Die Arbeit wurde bisher 8-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To investigate the parameters influencing vault after posterior chamber intraocular lens implantation, thereby establishing a formula to predict the vault after operation.

Methods

In this retrospective study, 61 patients (122 eyes) who underwent implantable collamer lens (ICL) implantation were enrolled consecutively from the Qingdao Eye Hospital of Shandong First Medical University, China, between August 2020 and October 2021. Comprehensive optometry, axial length, curvature, anterior chamber depth (ACD), lens thickness (LT), white-to-white distance (WTW), corneal thickness, sulcus-to-sulcus distance (STS), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL), ciliary-to-ciliary distance (CTC) and the distance between the ciliary-to-ciliary plane and the anterior crystalline lens surface (CTCL) were recorded preoperatively. The vault was measured by ultrasound biomicroscopy at 1 month after operation. The correlation among vault, preoperative parameters and ICL size was analyzed. The accuracy and reliability of the prediction formula were verified by analyzing the postoperative correlation coefficient of actual and predicted vaults of the contralateral eye and through the Bland-Altman consistency test.

Results

Parameters significantly influencing the vault at 1 month after operation are ACD (r=0.260, P=0.004), LT (r=-0.338, P

Schlagwörter

Stichwörter der Autor:innen

Ciliaryformulaimplantable collamer lens (ICL)vault

Autor:innen und Institutionen

  • Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.
  • State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China.
  • School of Ophthalmology, Shandong First Medical University, Qingdao, China.

Zitieren

APA

Cui, W., Wu, X., Ren, Q., Liu, K., Kong, F., & Wu, J. (2023). A new formula based on new parameters for predicting postoperative vault after posterior chamber intraocular lens implantation: a retrospective study. Quantitative Imaging in Medicine and Surgery, 13(9), 5502-5510. https://doi.org/10.21037/qims-22-1425

Vancouver

Cui W, Wu X, Ren Q, Liu K, Kong F, Wu J. A new formula based on new parameters for predicting postoperative vault after posterior chamber intraocular lens implantation: a retrospective study. Quantitative Imaging in Medicine and Surgery. 2023;13(9):5502-5510. doi:10.21037/qims-22-1425

BibTeX
@article{Cui2023,
  author = {Cui, Wei and Wu, Xiaoming and Ren, Qi and Liu, Kun and Kong, Fanqin and Wu, Jie},
  title = {A new formula based on new parameters for predicting postoperative vault after posterior chamber intraocular lens implantation: a retrospective study},
  journal = {Quantitative Imaging in Medicine and Surgery},
  year = {2023},
  volume = {13},
  number = {9},
  pages = {5502--5510},
  doi = {10.21037/qims-22-1425}
}
Kostenlos starten →