EUVIMEDEUVIMED entdecken
Open Access

Q.Liver software for the planning of treatment of liver cancer via transarterial radioembolization with yttrium-90 resin microspheres based on single-photon emission computed tomography-computed tomography

Dandan Shen, Xin Xie, Xin Zheng, Xutian Wang, Qi Wang, Lulu Yang, Yiqian Liang, Chenxia Li, Aimin Yang, Jianjun Xue iD

Quantitative Imaging in Medicine and Surgery · 2026-02 · 16 (2) · 109-109

DOI: 10.21037/qims-2025-1471 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2026-02. Verfasst von Dandan Shen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hepatocellular carcinoma (HCC) and liver-dominant metastases remain major causes of cancer mortality, and yttrium-90 transarterial radioembolization (TARE) offers a vital treatment option for unresectable cases. Accurate dosimetry is critical for maximizing tumor control while minimizing lung toxicity, yet conventional planar scintigraphy may overestimate lung shunt and compromise therapeutic efficacy. This study evaluated the value of Q.Liver software in planning yttrium-90 TARE for liver cancer.

Methods

A total of 45 patients with liver cancer scheduled for treatment with yttrium-90 resin microspheres TARE were enrolled. Treatment planning was conducted via the partition model with two approaches for each case: the traditional method based on planar scintigraphy and the Q.Liver software based on single-photon emission computed tomography-computed tomography (SPECT/CT) imaging. Differences in liver and lung volume between the two methods were compared. Differences in lung shunt fraction (LSF) were analyzed in 43 patients, and yttrium-90-prescribed activity, liver-absorbed dose (DLiver), and lung-absorbed dose (DLung) were compared between the two methods for the same patient. In the planar method, liver and lung volumes were obtained by enhanced CT, and LSF was obtained by planar scintigraphy; in the Q.Liver method, LSF, liver and lung volumes were obtained via SPECT/CT. The yttrium-90-prescribed activity, DLiver, and DLung of each method were calculated.

Results

(I) The liver and lung volumes in the planar and Q.Liver methods were 1,809 and 1,820 mL (P=0.36), respectively, and 3,279 and 2,587 mL (P

Schlagwörter

Stichwörter der Autor:innen

Lung shunt fraction (LSF)SPECTartificial intelligence (AI)transarterial radioembolization (TARE)yttrium-90

Autor:innen und Institutionen

  • Department of Nuclear Medicine, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
  • Department of Hepatobiliary Surgery, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
  • Department of Medical Imaging, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.

ORCID-Profile: Jianjun Xue

Zitieren

APA

Shen, D., Xie, X., Zheng, X., Wang, X., Wang, Q., Yang, L., Liang, Y., Li, C., Yang, A., & Xue, J. (2026). Q.Liver software for the planning of treatment of liver cancer via transarterial radioembolization with yttrium-90 resin microspheres based on single-photon emission computed tomography-computed tomography. Quantitative Imaging in Medicine and Surgery, 16(2), 109-109. https://doi.org/10.21037/qims-2025-1471

Vancouver

Shen D, Xie X, Zheng X, Wang X, Wang Q, Yang L, et al. Q.Liver software for the planning of treatment of liver cancer via transarterial radioembolization with yttrium-90 resin microspheres based on single-photon emission computed tomography-computed tomography. Quantitative Imaging in Medicine and Surgery. 2026;16(2):109-109. doi:10.21037/qims-2025-1471

BibTeX
@article{Shen2026,
  author = {Shen, Dandan and Xie, Xin and Zheng, Xin and Wang, Xutian and Wang, Qi and Yang, Lulu and Liang, Yiqian and Li, Chenxia and Yang, Aimin and Xue, Jianjun},
  title = {Q.Liver software for the planning of treatment of liver cancer via transarterial radioembolization with yttrium-90 resin microspheres based on single-photon emission computed tomography-computed tomography},
  journal = {Quantitative Imaging in Medicine and Surgery},
  year = {2026},
  volume = {16},
  number = {2},
  pages = {109--109},
  doi = {10.21037/qims-2025-1471}
}
Kostenlos starten →